READ THIS FIRST:
Check the pack and make sure you have all of the parts
listed on the front of this booklet. If not, contact the
outlet where you bought this product.
This product contains glass, care must be taken when
assembling, fitting or handling to prevent personal
injury or damage to the product.
This light fitting must be installed by a competent
person in accordance with the Building Regulations
making reference to the current edition of the IEE Wiring
Regulations (BS7671). The Building Regulations may be
obtained from OPSI or viewed and downloaded from
www.communities.gov.uk following the link for Building
Regulations.
As the buyer, installer and/or user of this product it is
your own responsibility to ensure that this fitting is fit
for the purpose for which you have intended it. Eterna
Lighting cannot accept any liability for loss, damage or
premature failure resulting from inappropriate use.
This product is designed and constructed according
to the principles of the appropriate British Standard
and is intended for normal domestic service. Using
this fitting in any other environments may result in a
shortened working life, for example where there are
prolonged periods of use or higher than normal ambient
temperatures such as lighting public or shared spaces or
in nursing / care home facilities.
The lamp supplied with this fitting is a consumable part
and therefore may be outside of any warranty offered.
Switch off the mains before commencing installation
and remove the appropriate circuit fuse.
When working at heights, please use a suitable platform.
Disconnect the fitting from the electrical supply before
flash or high voltage testing.
Suitable for indoor use only.
This product is suitable for use in living areas, and
Bathroom zone 2 and dry (Outside) zones only (see
diagram below and current IEE Wiring Regulations for
details). If being fitted in a bathroom a 30mA RCD must
be used.
This product is suitable for installation on surfaces with
normal flammability e.g. wood, plasterboard, masonry.
It is not suitable for use on highly flammable surfaces
(e.g. polystyrene, textiles).
Before making fixing hole(s), check that there are no
obstructions hidden beneath the mounting surface such
as pipes or cables.
The chosen location of your new fitting should allow
for the product to be securely mounted (e.g. to a ceiling
joist) and safely connected to the mains supply (lighting
circuit).
If the location of your new fitting requires the provision
of a new electrical supply, the supply must conform
with the requirements of the Building Regulations
making reference to the current edition of the IEE Wiring
Regulations (BS7671).
This product is designed for permanent connection to
fixed wiring: this should be either a suitable lighting
circuit (protected with a 5 or 6 Amp MCB or fuse) or a
fused spur (with a 3 Amp fuse) via a fused connection
unit. We recommend that the supply incorporates a
switch for ease of operation.
Make connections to the electrical supply in accordance
with the following code:
Live - Brown or Red
Neutral - Blue or Black
Earth - Green and Yellow
Where this product is used to replace an existing light
fitting, it will be necessary to remove any existing ceiling
rose to allow clearance for installation. If this is the case,
carefully note the existing position of each set of wires
(see diagram below). Where more than a single set of
L, N and E wires exist these must be transferred to a
separate approved junction box or terminal block (not
supplied) which must be insulated and placed within
the ceiling.
Additional red wires may be present in your ceiling
that are connected to the ring live circuit. Do not
connect your fitting to these wires. If these wires are
not terminated in a ceiling rose, join them together in a
separate terminal block (not supplied) and place in the
ceiling.
When making connections, ensure that the terminals are
tightened securely and that no strands of wire protrude.
Check that the terminals are tightened onto the bared
conductors and not onto any insulation. Wrap loose
terminal blocks well with insulating tape.
This product must be connected to Earth.
NOTE:
Very frequent switching can shorten the life of
the lamp . To minimise this, it is suggested to increase
the time to the maximum setting.
The bulkhead light (PIR version) incorporates a passive
infra red sensing device which continuously scans a
preset operating zone and immediately switches the
lamp on when it detects movement in that area. While
there is movement within range of the unit the lamp will
remain on.
You are advised at every stage of your installation to
double-check any electrical connections you have made.
After you have completed your installation there are
electrical tests that should be carried out: these tests are
specified in the Wiring Regulations (BS7671) referred to
in the Building Regulations.
WHERE TO FIT YOUR CEILING LIGHT:
To achieve best results, we suggest you take into account
the following points:
• For maximum detection range, the bulkhead light
should be mounted 1.8 to 2.5 meters (6 to 8ft) above
the area to be scanned. (see FIG. 1 below).
• To avoid nuisance triggering, the sensor should be
directed away from heat sources such as heaters/
radiators, air-conditioning outlets, other lighting, pet
entry/exit or sleeping areas etc.
• To avoid nuisance triggering, do not connect to the
same circuit as large fluorescent light fittings, bathroom
fans or other sources of mains borne noise (peaks and
spikes).
• The PIR Sensor scanning specifications (approximately
8 meters at approx. 120° - horizontal) may vary slightly
depending on the mounting height and location.
The detection range of the unit may also alter with
temperature change. Before selecting a place to install
your new fitting you should note that movement across
the scan area is more effective than movement directly
toward or away from the sensor. If movement is made
walking directly towards or away from the sensor
and not across, the apparent detection range will be
substantially reduced. (see FIG. 2 below).
LAMP REPLACEMENT:
1. Switch off the electricity at the mains.
2. Turn the three clips outwards to remove the diffuser.
3. Pull the lamp straight out of the gear tray inside.
4. Press the new lamp into position, take care to position
the lamp correctly over the lampholder.
5. Replace the diffuser, take care to position the inside
rim of the diffuser over the circumference of the rear
half of the fitting and the soft seal around the hole in
the diffuser over the PIR detector lens.
6. Press the diffuser in position and turn the three clips
to retain.
7. Restore the power and switch on.
REPLACEMENT LAMP TYPE:
Requires 1 x 28W GR10q 4pin DD CFL lamp (included).
Eterna replacement lamp product code:
DD28435
.
Fitting is rated at 28W max.
225cm
60cm
240cm
60cm
radius
from tap
ZONE 1
ZONE 0
ZONE 2
ZONE 2
Bathroom Zones Diagram
3.5m
120º
2.5m
360º
6m
12m
360º
12m
3.5m
120º
2.5m
360º
6m
12m
360º
12m
Fig 1
Fig 2
L
N
Yellow/Green
(Power Cable)
Blue
(Power Cable)
Brown
(Power Cable)
Yellow/Green
(Lamp Wire)
Blue (PIR Wire)
Brown (PIR Wire)