background image

To avoid damage to the unit do not aim sensor 

towards sun.
Avoid positioning the sensor unit adjacent to a 

bright light source which may prevent the unit from 

operating when the lux control is set to operate in 

dark conditions.
Avoid nuisance / false triggering by directing sensor 

away from:
• Trees and shrubs  

• Reflective surfaces such as smooth white walls 

• Swimming pools  

• Heat sources such as boiler flues
The PIR sensor scanning specifications 

(approximately 12 metres at 180°) may vary slightly 

depending on the mounting height and location.
The detection range of the unit may also alter with 

temperature change. Before selecting a place to 

install your PIR floodlight you should note that 

movement across the scan area is more effective 

than movement directly towards or away from the 

sensor. (Refer to fig.2 opposite). 

If movement is made walking directly towards or 

away from the sensor and not across the sensor 

the apparent detection range will be substantially 

reduced (refer to fig. 3 below).

INTRODUCTION:

The floodlight incorporates a PIR (Passive Infra Red) 

sensing device which continuously scans a preset 

operating zone and immediately switches the light 

on when it detects movement in that area.
This means that whenever movement is detected 

within the range of the sensor the light will switch 

on automatically to illuminate the area you have 

selected to light. While there is movement within 

range of the unit the light will remain on.
 

READ THIS FIRST:

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, 

contact the outlet where you bought this product.
This product contains glass, care must be taken when 

assembling, fitting or handling to prevent personal 

injury or damage to the product.
This product must be installed by a competent 

person in accordance with the current building and 

IEE wiring regulations.
As the buyer, installer and/or user of this product it 

is your own responsibility to ensure that this fitting 

is fit for the purpose for which you have intended 

it. Eterna Lighting cannot accept any liability for 

loss, damage or premature failure resulting from 

inappropriate use.
This product is designed and constructed according 

to the principles of the appropriate British Standard 

and is intended for normal domestic service. 
Switch off the mains before commencing installation 

and remove the appropriate circuit fuse or lock off 

MCB.
This unit is suitable for outdoor use.
This product is designed for permanent connection 

to fixed wiring: this must be a suitable circuit 

(protected with the appropriate MCB or fuse).   
Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.
Make sure that the fixings are strong enough to 

support the considerable weight of the fitting and 

hold it rigidly.
The lamp must be positioned so that there is at 

least 1M between the luminaire and any illuminated 

surface.
When making connections ensure that the terminals 

are tightened securely and that no  

strands of wire protrude. Check that the terminals are 

tightened onto the bared conductors and not onto 

any insulation. 
This product must be connected to earth 

termination.
This product is not intended to be used by children 

and persons with sensory, physical and/or mental 

impairments that would prevent them from using it 

safely.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation 

there are electrical tests that should be carried out, 

these tests are specified in the current IEE wiring and 

building regulations.
 

CLEANING:

•  To avoid dust build-up and ensure proper 

functioning of the floodlight, please wipe the 

sensor lens lightly with a damp cloth every 3 

months.

•  Disconnect the power and clean the exterior only of 

this fitting with a moist (not wet) cloth.

• Do not use any chemical or abrasive cleaners.
 

LAMP REPLACEMENT:

This luminaire has a sealed LED lamp and is 

maintenance free. No lamp replacement is required.

 

SPECIFICATIONS:

•  Detection range: max. 12M at approx. 180° scan

•  Duration time adjustment: (5-10) seconds to (8±1) 

minutes

• Detection circuitry: Passive Infra-Red (PIR)

• Weatherproof: IP44

• Power required: 230V~ 50 Hz

•  Recommended power supply cable: H05RN-F 3G 

1.0mm

2

 

• Protection: Class I

• Tempered glass
 

WHERE TO FIT YOUR PIR FLOODLIGHT:

To achieve best results we suggest you take the 

following points into consideration:
Do not mount on a surface that has vibration.
Ideally the PIR flood light should be mounted 1.8 to 

2.5 metres (6 to 8ft) above the area to be scanned 

(refer to fig.1 below).

INSTALLATION:

Terminal Block

Power

Cable

Lamp Cover Screws (in each corner)

Cable Gland

Wall Mounting

Support Screws

Wall Mounting

Support Bracket

Junction Box

Locking
Nut

L

N

Yellow/Green
(Power Cable)
Blue / White
(Power Cable)
Brown
(Power Cable)

Yellow/Green
(Earth)
Blue
(Power Cable)

Brown
(Power Cable)

(PIR Switch Wire)

(Lamp Wire)

2.5M

4M

8M

12M

180˚

Approx

Fig 1

Fig 4

EFFECTIVE:

Movement across

scan area

LESS EFFECTIVE:

Movement 

directly in front 

of scan area

Fig 2

Fig 3

PG 2

PG 3

Reviews: