READ THIS FIRST:

Check the pack and make sure you have all of the 

parts listed on the front of this booklet. If not, 

contact the outlet where you bought this product.

This product must be installed by a competent 

person in accordance with the current building and 

IEE wiring regulations.

 As the buyer, installer and/or user of this product it 

is your own responsibility to ensure that this fitting 

is fit for the purpose for which you have intended 

it. Eterna Lighting cannot accept any liability for 

loss, damage or premature failure resulting from 

inappropriate use.

This product is designed and constructed according 

to the principles of the appropriate British Standard 

and is intended for normal domestic service. Using 

this fitting in any other environments may result in 

a shortened working life, for example where there 

is prolonged periods of use or higher than normal 

ambient temperatures such as lighting public or 

shared spaces.

Switch off the mains before commencing installation 

and remove the appropriate circuit fuse or lock off 

MCB.

This unit is suitable for outdoor use.

This product is suitable for installation on surfaces 

with normal flammability e.g. wood, plasterboard 

and masonry.  It is not suitable for use on highly 

flammable surfaces 

Before making fixing hole(s), check that there are no 

obstructions hidden beneath the mounting surface 

such as pipes or cables.

Make sure that the fixings are strong enough to 

support the considerable weight of the fitting and 

hold it rigidly.

The chosen location of your new fitting should allow 

for the product to be securely mounted. And safely 

connected to the mains supply (lighting circuit).

When choosing the location for your new fitting, 

ensure that the fixings will be anchored in a solid 

surface e.g. concrete, brick or a joist—do not fix 

directly onto panelling, cladding, plasterboard etc.

When making connections ensure that the terminals 

are tightened securely and that no strands of wire 

protrude. Check that the terminals are tightened 

onto the bared conductors and not onto any 

insulation. 

This fitting is double insulated; do not connect any 

part to earth.

This product is not intended to be used by children 

and persons with sensory, physical and/or mental 

impairments that would prevent them from using it 

safely.

You are advised at every stage of your installation to 

double-check any electrical connections you have 

made. After you have completed your installation 

there are electrical tests that should be carried out, 

these tests are specified in the current IEE wiring and 

building regulations.

 

INSTALLATION:

ISOLATE MAINS BEFORE 

CARRYING OUT INSTALLATION

01)  Undo the nuts each side at the front of the fitting 

and lift off the front section of the lantern

02)  Using the back cover of the fitting as a template, 

mark the location of the fixing holes.

03)  Pierce the rubber grommet in the back of the 

fitting. Make the hole as small as possible so that 

a good watertight seal is maintained when the 

cable has been threaded through.

04)  Thread the cable through the grommet.

05)  Secure the fitting to the wall using fixings (not 

supplied).

06)  Make the connections to the terminal block 

according to the colour code and symbols: 

 

LIVE

 - Brown or Red • 

NEUTRAL

 - Blue or Black

07)  Connect the two wires from the front half of the 

lantern to the push terminal block in line with the 

colour code and symbols (see fig. 4 opposite).

08)  Replace the front part of lantern and secure by 

tightening the two nuts making sure you have a 

rubber sealing washer under both nuts.

09)  Restore power.

10)  Switch on and product should function.

 

SPECIFICATIONS:

•  Detection range: Approx. 120° (horizontal), Max. 8 

metres.

• Duration time: from 5 sec - 5 mins. (adjustable).

•  No override facility.

• LUX - adjustable.

 

LAMP REPLACEMENT:

 

WHERE TO FIT YOUR PIR FULL LANTERN:

To achieve best results we suggest you take the 

following points into consideration:

Do not mount on a surface that has vibration.

Ideally the PIR lantern should be mounted 1.8 to 2.5 

metres (6 to 8ft) above the area to be scanned (refer 

to Fig. 1 below).

To avoid damage to the unit do not aim sensor 

towards the sun.

Avoid positioning the sensor unit adjacent to a 

bright light source which may prevent the unit from 

operating when the lux control is set to operate in 

dark conditions.

Avoid nuisance false triggering by directing sensor 

away from:

Trees and shrubs 

Reflective surfaces such as smooth white walls 

Swimming pools  

Heat sources such as boiler flues

The PIR sensor scanning specifications 

(approximately 8 metres at 120°) may vary slightly 

depending on the mounting height and location.

The detection range of the unit may also alter 

with temperature change. Before selecting a place 

to install your PIR lantern you should note that 

movement across the scan area is more effective 

than movement directly towards or away from the 

sensor (refer to Fig. 2 above).

If movement is made walking directly towards or 

away from the sensor and not across the apparent 

detection range will be substantially reduced (refer 

to Fig. 3 above).

1.8-

2.5M

4M

8M

120˚

Approx

Fig 1

EFFECTIVE:

Movement 

across scan area

LESS EFFECTIVE:

Movement directly in front of 

scan area

Fig 2

Fig 3

L

N

Blue
(Power Cable)

Brown
(Power Cable)

Blue
(Power Cable)

Brown
(Power Cable)

Fig 4

The light source contained in this luminaire 

shall only be replaced by the manufacturer, 

service agent or a similar qualified person. 

CAUTION, RISK OF ELECTRIC SHOCK.

The light source is designed to last the lifetime of the 

luminaire.