TMCM-1310 TMCL Firmware V1.11 Manual (Rev. 1.16 / 2014-MAR-19)
73
www.trinamic.com
Number Axis Parameter Description
Range [Unit]
Acc.
173
stallGuard2 filter
enable
Enables the stallGuard2 filter for more
precision of the measurement. If set, reduces
the
measurement
frequency
to
one
measurement per four fullsteps.
In most cases it is expedient to set the
filtered mode before using coolStep.
Use the standard mode for step loss
detection.
0 – standard mode
1 – filtered mode
0/1
RW
174
stallGuard2
threshold
This signed value controls stallGuard2
threshold
level for stall output and sets the
optimum measurement range for readout. A
lower value gives a higher sensitivity. Zero is
the starting value. A higher value makes
stallGuard2 less sensitive and requires more
torque to indicate a stall.
0 Indifferent value
1… 63 less sensitivity
-1 -64 higher sensitivity
-64… 63
RW
175
Slope control
high side
Determines the slope of the motor driver
outputs.
Set to 2 or 3 for this module or
rather use the default value.
0: lowest slope
3: fastest slope
0… 3
RW
176
Slope control
low side
Determines the slope of the motor driver
outputs.
Set identical to slope control high
side.
0… 3
RW
177
Short protection
disable
0: Short to GND protection is on
1: Short to GND protection is disabled
Use default value!
0/1
RW
178
Short detection
timer
0: 3.2µs
1: 1.6µs
2: 1.2µs
3: 0.8µs
Use default value!
0… 3
RW
179
Vsense
Sense resistor voltage based current scaling
0: 0… 3A
1: 0… 1.5A
higher solution
0/1
RW
180
smartEnergy
actual current
This status value provides the
actual motor
current
setting as controlled by coolStep. The
value goes up to the CS value and down to
the portion of CS as specified by SEIMIN.
actual motor current scaling factor:
0 … 31: 1/32, 2/32, … 32/32
0… 31
RW
181
Stop on stall
Below this speed motor will not be stopped.
Above this speed motor will stop in case
stallGuard2 load value reaches zero.
0… +327.679.999
[pps]
RW
182
smartEnergy
threshold speed
Above this speed coolStep becomes enabled. 0… +327.679.999
[pps]
RW
183
smartEnergy
slow run current
Sets the motor current which is used below
the threshold speed.
0… 255
RW