31
EN
Main menu: Fitter
Installed
output
Preset to
400 W.
Adjustable.
Required to display energy
consumption.
Features
Adaptive
function
On/Off (preset On)
Read more on page 20.
Ventilation
function
On/Off (preset On)
Read more on page 20.
Delayed start
Should heating be started
in 4 weeks time?
OK/No
Operating
time limita-
tion
The underfloor heating is
turned off for x minutes
per hour.
Preset to Off
Adjustable 1
–
15 min
Reset
Reset all
Save data
Saving energy consumption.
Other settings will be reset.
Operating information
Right now
Display of the
current temp.
and sensors.
In X: XX
(time in hours
until setpoint
is reached)
Set
Set point reached.
Limited
Maximum or minimum
limitation is activated. The
function is activated under
Sensor selection. Read more
on page 30.
Ventilation
The ventilation function turns
the heat off for 15 minutes if it
detects that the temperature
drops by more than three
degrees in less than one
minute.
Operating information
The thermostat display shows the opera-
ting information under the setpoint.