11
12
No.
Name
Default
Range
1
Sensor selection
00: Floor sensor
00: Floor sensor
01: Room-in sensor
02: 01+00
03: Room-out sensor
04: 03+00
2
Room temp calibration
0.0
°
C
-5.0
°
C - 5.0
°
C
3
Floor temp calibration
0.0
°
C
-5.0
°
C - 5.0
°
C
4
Floor temp limit
35.0
°
C
20.0
°
C - 50.0
°
C
5
Schedule
01: 5+1+1
00: 7
01: 5+1+1
6
Used for
00: Heating
00: Heating
01: Cooling
There are 5 options:
00 Floor sensor: floor sensor mode (default).
01 Room-in sensor: built-in room sensor mode.
02 Room-in sensor and floor sensor: built-in sensor mode with floor temperature limit.
03 Room-out sensor: external room sensor mode.
04 Room-out sensor and floor sensor: external room sensor mode with floor temperature limit.
Parameters
2. Room temp calibration: calibrate the temperature detected by room sensor.
3. Floor temp calibration: calibrate the temperature detected by floor sensor.
4. Floor temp limit: if you choose both sensors, floor temp limit must be set to protect
the floor.
5. Schedule: Select a weekly schedule for the event.
1. Sensor selection:
7: each day from Mon to Sun can be set individually.
5+1+1: 5 days from Mon to Fri have the same events, Sat and Sun can be set individually.
6. Used for: heating or cooling.
There are 2 options: