29
Temperature menu
TEMP
The temperature menu contains the functions that in some way concern direct
temperature regulation. This is where the temperature range and temperature
hysteresis are set. The temperature menu is reached via
TEMP
in the
MAIN MENU
.
Temperature range
RANGE
You find the temperature range settings under
TEMP
in the temperature menu.
This function is used to set the temperatures which the thermostat is active
between. The max value is the upper temperature in the range and min value is
the lower temperature.
If the max value is set to +2 °C and the min value to -10 °C, the thermostat is
activated when the temperature falls to +2 °C; if it falls further, to below -10 °C,
the thermostat is deactivated again until the temperature rises to within the set
temperature range.
The Max/Min operating position is mainly used to keep roof and ground
surfaces free of snow and ice. The temperature range is adjustable between
-20 °C and +10 °C. For the best results and the best energy saving, combined
temperature and humidity control should be used in the Max-/Min position,
with associated Roof Sensor or Ground Sensor.
To use the thermostat in Max/Min mode for roof installation, you will
probably need to complement with IP54 outdoor encapsulation and Roof
sensor. The encapsulation should be placed where it is permanently shady,
e.g. on the north side or shady side. Ensure that it is not affected by heat
emittance from the building or a heating cable.
Main menu
MAIN MENU
The
MAIN MENU
contains three submenus:
TEMPERATURE
,
PROGRAM
and
SYSTEM
.
From display mode, go to the
MAIN MENU
by pressing
once. Use the
or
button to move between the menus, and confirm using
.
If you do not press a button for 30 seconds, the thermostat returns to display
mode; you can also return to display mode by selecting
EXIT
.
Operation mode Max/Min
PROGRAM
TIMER
EXIT
SYSTEM
LANGUAGE
DATE/TIME
S/W TIME
SENSOR
RESET
EXIT
EXIT
DISPLAY MODE
M
AIN MENU
TEMP
RANGE
+HEATING