background image

 

LZ bracket for Inswing doors

 

Connecting Diagram

+

+

-

-

N.O.

COM.

N.C.

Power 

Input

Power

supply

S

P

D

relay

 

0.

5A/125V

AC

1A

/24

V

D

C

 

12VDC

24VDC

Voltage Selection Jumpers

Check jumper settings before 

connecting the lock to 24 VDC 

input power. Damage to the 

lock may result from incorrect 

jumper settings.

Problem                                           Possible Cause                                                                        Solution

Door does not lock

No power

Poor contact between electromagnet and 

armature plate

Low voltage or incorrect voltage setting

A secondary diode was installed across 

the electromagnetic lock

Misalignment between the armature plate

and electromagnetic lock

Make sure the wires are connected properly
Check that the power supply is connected and works properly
Make sure the lock switch is wired correctly (N.C.)
Make sure if the armature plate is not misaligned

Make sure the contact surfaces of the electromagnet and armature plate are clean 

and free from dust

Make sure the armature plate and electromagnetic lock are aligned correctly

Make sure if the rubber washer was used between the bracket lock and armature plate

Check the electromagnet lock is set for the correct voltage.

Check the voltage at the of input electromagnetic locks. If low, determine if the 

correct wire gauge is being used to prevent excessive voltage drop.

Remove any diode installed across the magnet for "spike" 

suppression. (The magnet is  fitted with a metal oxide varistor to prevent back EMF)

Low holding force

Sensor output is not functioning

 

Trouble Shooting

2

Use  the  fixing  bolt  to  tighten  the 

electromagnetic lock on L bracket.

1

Find  a  mounting  location  on  the 

door frame for the L bracket.  Make 

sure that the door is still closeable.

6

Close the door and connect the

power.

4

Insert the guide pins into the 

armature plate.

5

3

N.C. contact output: open status

N.O. contact output: locked status

Relay rating output needs to meet the instruction of PCB

7

Power

Outdoor

Finish

Power

Outdoor

Assemble  the  Z  bracket,  and 

make sure that the position of the 

Z bracket is adjustable.

Fasten the armature plate to the 

Z bracket (Rubber washer must 

be added).

After  the  maglock  attracts  the 

armature  plate,  adjust  the 

position between Z bracket and 

the door. Then fix the Z bracket.

Connect  the  power,  close  the 

door and test the unit.

Control Device N.C. contactor Access Relay

Bonds sensor output