ENVR208
If not, please contact the engineer from our company to do the further process.
The IP camera frequently goes online and offline and the status of it displays as
“Disconnected”.
Possible Reasons:
−
The IP camera and the device versions are not compatible.
−
Unstable power supply of IP camera.
−
Unstable network between IP camera and device.
−
Limited flow by the switch connected with IP camera and device.
Step 17
Verify the IP camera and the device versions are compatible.
13)
Go to Menu>Camera, and view the firmware version of connected IP camera.
14)
Go to Menu>Maintenance>System Info>Device Info and view the firmware version of
device.
Step 18
Verify power supply of IP camera is stable.
15)
Verify the power indicator is normal.
16)
When the IP camera is offline, please try the ping command on PC to check if the PC
connects with the IP camera.
Step 19
Verify the network between IP camera and device is stable.
17)
When the IP camera is offline, connect PC and device with the RS-232 cable.
18)
Open the Super Terminal, use the ping command and keep sending large data packages
to the connected IP camera, and check if there exists packet loss.
Simultaneously press
Ctrl
and
C
to exit the ping command.
Example:
Input ping 172.6.22.131 –l 1472 –f.
Step 20
Verify the switch is not flow control.
Check the brand, model of the switch connecting IP camera and device, and contact with the
manufacturer of the switch to check if it has the function of flow control. If so, please turn it
down.
Step 21
Check if the fault is solved by the step 1 to step 4.
If it is solved, finish the process.
If not, please contact the engineer from our company to do the further process.
⚫
No monitor connected with the device locally and when you manage the IP camera to
connect with the device by web browser remotely, of which the status displays as Connected.
Summary of Contents for ENVR208
Page 1: ......
Page 44: ...ENVR208 Result You can view all of the channels in one screen using the CMS or web browser ...
Page 108: ...ENVR208 Figure 11 12 Alarm Output ...
Page 131: ...ENVR208 Figure 14 8 Set Trigger Cameras of POS Step 8 Click Apply ...
Page 140: ...ENVR208 Figure 15 8 Port Settings ...
Page 167: ...ENVR208 Chapter 19 Appendix 19 1 Specifications ...