background image

Set Master Code

Programming Step

Keystroke Combination

1. Enter Program Mode
2. Update Master Code

3. Exit

Please do remember your Master Code because the Master Code can’t be reset if forget it.

* (Master Code) # 
0

New Master Code

#

Repeat New Master Code

Master code is any 6 digits
*

Add Users PIN(s)

Programming Step

Keystroke Combination

1. Enter Program Mode
2. Add PIN

3. Exit

User ID: 0~499
PIN length: 4~8 digits

* (Master Code) # 
1 (User ID) # (PIN) # (Repeat PIN) #
The users can be added continuously
*

Add Users Card(s)

Programming Step

Keystroke Combination

1. Enter Program Mode:
2. Add Card: 
     Using Auto ID(Allows to assign Card 
     tonext available User ID number)
                      OR
2. Add Card: 
     Select Specific ID(Allows Master to 
     define a Specific User ID to associate 
     the card)
3. Exit:

User ID: 0~499
Card type: 13.56MHz M1 Card

* (Master Code) # 
1 (Read Card) # 
The cards can be added continuously.

1(User ID) # (Read Card) #

*

Change PIN

Programming Step

Keystroke Combination

1.Change PIN: 
    By Card(There will be auto allocate 
    PIN (8888) to cards when adding)
                      OR
    Change PIN: By User ID

2. Exit:

Note: Below is done outside programming mode, users can undertake this themselves

*  (Read Card) (Old PIN) # (New PIN) #
(Repeat New PIN) #

*  (User ID) # (Old PIN) # (New PIN) #
(Repeat New PIN) # 
Exit automatically

Summary of Contents for ES-DLS-01

Page 1: ...ES DLS 01 Wireless Security DockLock Base Set www etiger com ON OFF ON OFF ...

Page 2: ......

Page 3: ......

Page 4: ...ng3Mstickersprovideasimplewayforinstallation nodoordestroy no hole wireless nopowercab 433MhzRollingCodeofencryptionalgorithmandthesplitdesign guaranteehigher secure TheKeypadcanstore500PIN cardusers Becauseofultralowpowerconsumption theKeypad andRemoteTransmitterscanworkaslongasoneyear baseson30times day WirelessLock canwork6months Itwillremindpeopletoreplacebatteriesintelligentlyiflowbattery 500...

Page 5: ...Keypad WirelessLock OperatingHumidity Physical WirelessLock RemoteTransmitter Dimensions WirelessLock RemoteTransmitter UnitWeight WirelessLock RemoteTransmitter 500 4 8Digits 13 56MHzM1Card 2unitsofAAbatteries 1unitof2032Lithiumbattery Allitems 10uA 42mA 3mA 433MHz 50mMaximum 40 C 60 C 40 F 140 F 20 C 60 C 4 F 140 F 0 86 RH Zinc Alloy ABSShell ABSShell L150 W95 D39 mm L55 W32 D10 mm 800g 16g pc S...

Page 6: ...Major Parts ON OFF ON OFF ...

Page 7: ...uretheHaspalignthe doorframe SopleasemakesurethedirectionofHaspisfitformainbodyoflockbeforeinstallation Attentions of installing the Hasp PuttheLocatingRingsintoHasp andstickthe3MstickeratthebacksideofHasp Youcan screwthehaspontheReinforcingPlateifneeded thenstick3Mstickeratthebackofplate It canincreasethestickareatomaketheHaspstronger Installing the Hasp FixthemainbodyoflockandtheFixedPlatebyM5 6...

Page 8: ... Note Mechanical Switch it is used for installation and equipment trouble please don t press it often in the normal condition When press the Mechanical Switch the lock will be unlock all the time until open the door one time by valid card or valid PIN or touch the close icon on the lock or unlock button on RemoteTransmitter Method 2 Install by screws OPEN CLOSE OPEN CLOSE 87mm 61mm ...

Page 9: ...itter ByWirelessLock LockImmediately ByKeypad ByRemoteTransmitter ByWirelessLock FingerprintAccess Enter and Exit Program Mode Operation 123456 123456isthefactorydefaultmastercode 0 NewCode RepeatNewCode code 6digits 1 UserID PIN RepeatPIN 1 ReadCard 1 UserID Readfingerprint RepeatReadfingerprint 2 UserID 2 ReadCard PIN ReadCard Press Touch Press 0 Press Touch ReadFingerprint ProgrammingStep Keyst...

Page 10: ...Card s ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 AddCard UsingAutoID AllowstoassignCard tonextavailableUserIDnumber OR 2 AddCard SelectSpecificID AllowsMasterto defineaSpecificUserIDtoassociate thecard 3 Exit UserID 0 499 Cardtype 13 56MHzM1Card MasterCode 1 ReadCard Thecardscanbeaddedcontinuously 1 UserID ReadCard Change PIN ProgrammingStep KeystrokeCombination 1 ChangePIN ByCard ...

Page 11: ...userscanbedeletedcontinuously 2 ReadCard 2 MasterCode Set Access Mode ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 Ad2 PINAccess OR PIN CardAccess OR PINorCard 3 Exit MasterCode 30 31 32 factorydefault ProgrammingStep KeystrokeCombination 1 EnterProgramMode 2 Strike OutOFF OR Strike OutON 3 Exit MasterCode 60 factorydefault 61 Set Buzzer ProgrammingStep KeystrokeCombination 1 EnterPro...

Page 12: ...othis operationinusing PairWireless Keypad RemoteTransmitter withWireless Lock CLOSE Note 1 TheWirelessLockcanpair16parts Keypad RemoteTransmitter maximum 2 Whenpairing allpartsmustbepaired thenexitparingmode Ifneedaddingonemore part youstillneedtopairallpartsagain Step 1 Enter pairing mode OpenthebatterycoverofWirelessLock pressthesmallroundbuttonleftofbattery withaslenderrod holditfor2secondsunt...

Page 13: ... Trans mitter Exitfromthe program mode Anykeypresslow batteryiconturn on5 Sthenoff Lowbattery reminding Pairing ON Unlock thelock Lock Lock Lowbattery reminding LEDshining andbeeps Pressbutton RedLED Note Thelockwillopenautomaticallywhenthebatteryis tooloworrunout pleasechangethebatteryINTIME ONfor3 seconds Green LED Lowbattey ICON Whenthe LEDisdim pleasechange thebattery Buzzer Onebeep Onebeep On...

Page 14: ...Name Packagingbox WirelessLock RemoteTransmitters Manual ScrewDriver WallFixingPlus SelfTappingScrews AccessoriesofWirelessLock 3MStickers Packing List Quantity 1pc 1pc 2pcs 1pc 1pc 4pcs 4pcs 4sets 4pcs ...

Reviews: