“save curve”
,
can save current parameter and flow curve.
In parameter setting display, can set parameter, setting range refer to 5.1.
T0: only satisfy “TIR≥T0”, top infrared heater can start working. No special purpose, please set Tir
>
T0.
Can also click “flow select” in “edit flow display”, call saved parameter and modify it. heat dissipation
air quantity: 35
~
100.
Note: parameter setting please refer to technology require.
11.4 curve analysis interface
1.
Curve analysis display: this display can analysis KT1
-
KT3 flow curve, know peak temperature of this
flow, temperature rise slope, temperature change of every heat process and time, thus judge if
correspond technology flow.
2.
In curve analysis interface, can save or delete current curve, or call saved curve analysis, and also print
current curve file.
3.
After open flow file, flow curve interface auto display flow curve; if flow file contains external K type
temperature test data, then display temperature arise time, maximum temperature rise slope, peak
temperature.
11.5 advanced setting interface
Advanced setting: in this interface, we can set operation limits of authority, communicate video etc. and also
can set T0, temperature curve color and wire wide, and can select china and English.
Data analysis
interface