BGA ETA-H15 OPERATION MANUAL
Page7
L.
Function of “YELLOW” key: rotate it, adjust yellow light of camera; press it, close the light.
8. IR System Operation
8.1 Part Function
* Adjust the Aperture System
The Aperture System of Top Radiator can be adjust from 20×20 (mm) to 60×60 (mm) by two Adjustment
Knobs. Unscrew the knobs before adjusting, and adjust the window size, then tighten knobs. The scale “2” on
the housing means 20mm and “3’ means 30mm, other scale is similar. For example, if you want to adjust size
to 50×50(mm), adjust two knobs to the scale of “5” and tighten them.
Note:
Adjusting the aperture system can protect the adjacent components on the PCB from being heated. But, when
the aperture system is adjusted to small size, the Top Radiator will be very hot and decrease its lifetime, so
it’s necessary to increase the window size appropriately to avoid the damage of the Top Radiator.
8.2 Parameters Setting
Parameter settings order as the follows:
A
.
_password: ***
(
Password settings
)
B
、
_select: 0
(
Flow settings, it can modify parameter inside).
C
.
_type: solder
(
Working mode settings
)
D
.
_laser: off
(Laser alignment settings)
E
.
_baud: 19200
(
Communication speed settings
)
A. Input password
The initial password of system is “000”. At the same time, system also has the omnipotent password “159”. If
Scale
Adjustment knob
Summary of Contents for BGA ETA-H15
Page 2: ......