background image

3.

 

Characters 

 

 

Closed-loop sensor controls the temperature and zero triggering without interfering with the 

voltage 

 

With the special metal (anti-erosion and heat-resistant) and the life putting into service for lead 

free is long 

 

Heating speed is rapid and the temperature is stable and accuracy 

 

Smart design and it is easy to use. 

4.

 

Specifications Q200/Q400 

 

 

Power:   

 

 

200/400W 

 

Size of the solder pot:   

36 H40mm / 

54 H38mm 

 

Temperature range: 

 

150

~500

℃ / 

150

~450

 

 

Temperature stability:   

±5

 

 

Weight:

  

 

1kg /1.34kg (including power cord) 

 

Dimension: 

 

 

91(L)*150 (W)*75 (H) mm / 190(L)*115 (W)*75 (H) mm 

5.

 

Operation 

 

Warning:  the using voltage must be identical with the rated voltage of the escutcheon. 

 

1)

 

Put the solder pot on the flat workbench which is heat-resistant or put a metal plate under the 
solder pot 

2)

 

Put  condign  soldering  tin  to  the  pot  and  the  maximal  position  of  the  soldering  tin  must  be 
under the pot’s top 5mm 

3)

 

Connect with the three wire-grounding socket 

4)

 

Turn on the power knob and then the unit comes to heat. At the time, the red LED is on 

5)

 

Adjust the temperature-adjusting knob to the needed temperature scale 

6)

 

It needs spend some time to melt the soldering tin, such as ten minutes from 25

 to 300

. It 

can put into service when the soldering tin has melted and the LED is twinkle or darkle. If there 
are some oxides floating on the surface, it must clear off the oxides and keep the soldering tin 
clean 

7)

 

It must turn off the power switch to cool the unit after finishing work 

 
 

6.

 

Temperature calibration  

 

It should be recalibrated after replacing the pot or the heating element. 
 

1)

 

Set the temperature of the unit to 300

 

2)

 

When  the  temperature  of  the  unit  stabilizes,  dip  the  outer  temperature  sensor  of  the 
thermometer  into  the  pot  and  view  the  value  when  the  temperature  of  the  thermometer 
stabilizing 

3)

 

If the value of the thermometer’s temperature is not 300

, calibrating the temperature. Use a 

straight – edge (-) screwdriver or small plus (+) screwdriver to adjust the screw (marked CAL) 
until  the  thermometer indicates  a  temperature

 

of  300

.  Turn  the screw  clockwise to  reduce 

the temperature and counterclockwise to increase the temperature 

Summary of Contents for Q200

Page 1: ... Lead Free Soldering Pot INSTRUCTION MANUAL Q200 400 1 Safety Instruction WARNING Please read this instruction manual before operating the unit for avoiding the accident The unit must use three grounding cord and socket for good ground including the prolonging power cord Do not use the unit to other task except to melt the soldering tin ...

Page 2: ...or avoiding accident No use the unit in the damp surrounding No use the unit with the broken power cord When the temperature is above 300 it will oxide the soldering tin and shorten the life of the unit Use the unit at the as lower temperature as possible When using the unit for the fist time please set a lower temperature such as 300 at fist and then wait unit the temperature is stable it can adj...

Page 3: ...b and then the unit comes to heat At the time the red LED is on 5 Adjust the temperature adjusting knob to the needed temperature scale 6 It needs spend some time to melt the soldering tin such as ten minutes from 25 to 300 It can put into service when the soldering tin has melted and the LED is twinkle or darkle If there are some oxides floating on the surface it must clear off the oxides and kee...

Page 4: ...er pot is not heating If the power supply and the fuse are both in gear at the moment it can judge the sensor is in malfunction B Because the pot may be eroded after using a period of time it must check the pot periodically Suggest If using lead soldering tin it should check at least one time each year as the setting temperature is 250 and the work time is five days each week and eight hours every...

Reviews: