Summary of Contents for TG72B12

Page 1: ...1 Eastern Tools Equipment Inc TG72B12 Portable Generator 8250 Surge Watts 7250 Continuous Watts Customer Service 888 908 6200 www easterntools com Eastern Tools Equipment Inc Ontario CA U S A ...

Page 2: ...e questions operating advice and or assembly questions This manual will explain how to operate and service your generator set Please fill out the information below This will help you save time if you ever need to provide the following information for a warranty repair GENERATOR Model Number _________________________________________ Serial Number __________________________________________ ENGINE Mo...

Page 3: ...power Use approved transfer equipment to isolate the generator from electric utility In highly conductive area such as metal decking or steel work use a ground circuit fault interrupter Never touch the generator if the generator is wet Also never touch the generator if your hand is wet Never operate your generator if the weather conditions call for any type of precipitation such as rain snow or fo...

Page 4: ...er grade of oil for your operating environment 1 Remove the oil drain plug with a 15 mm socket and extension 2 Allow the oil to drain completely 3 Replace the drain plug 4 Remove oil fill cap dipstick to add oil 5 Add 33 8 oz 1 L of oil and replace oil fill cap dipstick 6 Dispose of used oil at an approved waste management facility Oil capacity is 33 8 oz 1 L SPARK PLUGS 1 Remove the spark plug ca...

Page 5: ... SET ASSY 9 WHEEL 10 20 TANK COMP FUEL 10 BATTERY KICKSTAND 21 FRAME ASSY 11 CIRCUIT BREAKER 20A WARNING DO NOT exceed the generator s wattage amperage capacity Our products are continuously being changed and improved Every effort has been made to ensure that information in the manual is accurate and up to date However we reserve the right to change alter or otherwise improve the product and this ...

Page 6: ...it Flat Head Screwdriver Spark Plug Wrench Wrench 8 10 17 19 Battery Wire 1 3 Assembly Kit Wheel 2 pcs 1 4 Assembly Kit Wheel Kit Hardware 1 5 Assembly Kit etc Generator Foot 2 pcs 1 6 Assembly Kit Handle 1 7 吊钩Suspend Conveyance Suspend 1 8 Owner s manual 1 ...

Page 7: ... cable to the positive end and fasten it b After attaching the cable to the anode please remember to attach the rubber safety over the anode as illustrated in this picture c Connect the other end of the red cable to the output end relay 2 CONNECTING THE BATTERY S CATHODE a Connect one end of the white cable to the negative end and fasten it b After attaching the cable to the cathode Please remembe...

Page 8: ...enerator run at no load for several minutes to stabilize internal temperatures of the engine and generator 3 Turn the ignition switch to the Off position 4 Turn the fuel valve to the Off position MAINTENANCE Generator maintenance consists of keeping the unit clean and dry Be sure to store the unit in a clean and dry environment where it will not be exposed to excessive dust dirt moisture or any co...

Page 9: ...he cover spring RECEPTACLES This generator is equipped with the following Receptacles NEMA 5 20R 125 Volt 20 Amp GFCI Duplex Receptacle L5 30R 120V 30Amp Twist Lock Receptacle L13 30R 120V 30Amp Twist Lock Receptacle STORAGE The generator should be started at least once every week If this cannot be done and you must store the unit more than 30 days please follow the following guidelines Close the ...

Page 10: ...engine with new oil to the filter neck Pull the starter grip carefully until resistance is felt Store the generator in a clean area MAINTENANCE Below is a routine maintenance schedule 1 These items should be serviced by a dealer 2 Every 3 years ...

Page 11: ... power or overheating Generator is overloaded Review load and adjust See Power Management Insufficient ventilation Check for air restriction Move to a well ventilated area No AC output Cable not properly connected Check all connections Connected device is defective Replace defective device Circuit breaker is open Reset circuit breaker Capacitor defective Replace capacitor Service Center Faulty bru...

Page 12: ...12 WIRING DIAGRAM ...

Page 13: ...13 Parts List ...

Page 14: ...14 ...

Page 15: ...15 ...

Page 16: ...16 ...

Page 17: ...17 ...

Page 18: ...18 ...

Page 19: ...r use means personal residential household use by a retail consumer Commercial use means all other uses including the commercial income producing or rental purpose Once the engine has experienced commercial use it shall thereafter be considered as a commercial use engine for purpose of this warranty Engines use in competitive racing or commercial or rental tracks are not warranted A two year warra...

Page 20: ...mblies such as clutches transmissions remote controls etc which are not manufactured by Eastern Tools Equipment Inc 6 Damage or wear to parts caused by dirt which entered the engine because of improper air filter maintenance re assembly or use of a non original air filter element or cartridge Read Operating Maintenance Instructions 7 Parts damaged by over speeding or overheating caused by grass de...

Page 21: ...c o Service Manager Engine and Equipment Service Division IMPORTANT NOTE This warranty statement explains your rights and obligations under Emission Control system Warranty ECS Warranty which is provided to our by Eastern Tools Equipment Inc pursuant to California law Eastern Tools Equipment Inc also provides to original purchasers of new Eastern Tools Equipment Inc engines Eastern Tools Equipment...

Page 22: ..._______________________________ State_____ Zip Code___________________ Province or County______________________________________________________________ Are you a Business Residence Product Usage Information How often will you use this product Everyday Periodically Emergency Use Only Other What type of application will you use this product in Heavy Commercial Moderate Commercial Light Commercial Tr...