50
RDT-07-0122
®
NORD
fire
|
FDMQ
www.etsnord.com
11. Noise data
11.1 Level of acoustic output corrected with filter A.
11.2 Level of acoustic output in octave ranges.
11.3 Table of acoustics values
Tab 11.3.1.Level of accoustic output L
W
₁ [dB] related to the 1 m² section
Tab 11.3.2. Correction to the weight filter A
v
[m/s]
2
3
4
5
6
7
8
9
10
11
12
[dB]
-15,0
-11,8
-9,8
-8,4
-7,3
-6,4
-5,7
-5,0
-4,5
-4,0
-3,6
level of acoustic output corrected with filter A
level of acoustic output related to the 1 m² section (see Tab. 11.3.1.)
duct cross section
correction to the weight filter A (viz Tab. 11.3.4.)
level of acoustic output corrected with filter A
level of acoustic output related to the 1 m² section (see Tab. 11.3.1.)
duct cross section
correction to the weight filter A (viz Tab. 11.3.4.)
L
Woct
= L
W1
+ 10 log(S) + L
rel
L
Woct
[dB]
L
W1
[dB]
S
[m
²
]
L
rel
[dB]