background image

  

www.ets-products.com

  

 

   

7

  

 

  

AP-40 

User Manual

 

 

 

 

Manual Adjustment of 

Purification

 Level 

 

 

The air purification level can be set manually in 4 levels as required:  quiet, low, middle, 
high. The air quality sensor continues to work and is not 

affected

 by the respective setting.

 

 

 

 

 

Removal of Formaldehyde and Sterilization

 

 
 

The  device  is  equipped  with  a  special  nano photocatalytic  filter  and  UV  sterilization 
system.  This  function  is  not  activated  at  the 

rst  start.  It  can  be  activated  manually  by 

touching the symbol         . Repeated touch deactivates the function again.

 

 
 
 
 

 

Summary of Contents for AP-40

Page 1: ...40 User Manual Thank you for buying our air purifier Each unit has been carefully manufactured to ensure safety and reliability Please read the instructions carefully before first use and keep the ma...

Page 2: ...tion 0 005 mg m Automatic Mode yes Remote Control IR Operation Touch Air Quality Display Colorchange Sensor PM2 5 Pre Filter yes HEPA Filter medical grade H13 PP PET Activated Carbon Filter honeycomb...

Page 3: ...epend on the standard of the country or region in which the devices are intended of being used The device data can be found on the product label Use only devices that are suitable for your region Pack...

Page 4: ...cluding HEPA H13 filter activated carbon filter with high iodine content TIO2 photocatalyst filter plasma and UV sterilization lamp with a wave length of 254 nm It can remove PM 2 5 formaldehyde benze...

Page 5: ...evicehorizontallyupright 2 Pleasemakesurethattherearcase coveristightlyclosed 3 Insert the power plug into the back of the device as shown 4 After connecting to the power grid you will hear a beep ind...

Page 6: ...nce based on the currentairquality Air Quality Sensor The air puri er has a highly sensitive air dust sensor In milliseconds the sensor gives the puri er a command to adjust the puri cation performanc...

Page 7: ...ddle high Theairqualitysensorcontinuestoworkandisnota ected by the respective setting Removal of Formaldehyde and Sterilization The device is equipped with a special nano photocatalytic filter and UV...

Page 8: ...tand by mode Press repeatedly to choose the desired setting By activating the sleep mode all indicator lights are switched off the cover of the main air duct is closed and the cleaning cycle is now di...

Page 9: ...pressing the button the control panel will be locked The device in this mode can no longer be set by using the control panel Press againtounlock the control panel Multi Layer Air Filter Pre Filter HE...

Page 10: ...t Thenputitback inthedeviceandkeepusingit 2 Photocatalytic Nano Filter This lter can be cleaned regularly using a vacuum cleanertoremovesurfacedust Itcancontinue tobeusedaftercleaning 3 Dust cover of...

Page 11: ...iately Resettimer Press the HEPAReset button andhold itdownfor5secondsafterchanging the lter Alongbeepindicatesthatthetimerhasbeenreset 5 UVlamp theairpuri ersavestheusagetimeandremindsyoutoreplace th...

Page 12: ...o the power grid check that the voltage and frequency indicated on the product label matches thevoltage and frequencyusedinyourregion Iftheplug powercordorcaseisdamaged donotusetheproduct Keepchildren...

Page 13: ...cts Philippines Inc Berthaphil IV Warehouse 2C Civil Aviation Complex Clark Freeport Zone Pampanga 2023 Philippines Contact Asia Contact Europe Phone 63 0 45 499 5607 Email inquiry ets products ph Pho...

Reviews: