SMI17 Microphone Kit Instructions
The SMI17 is a 16 channel, one way, pre-amplified microphone “listen in” surveillance kit designed to be used in
applications where an audio amplifier (speaker) is not needed or is already provided in CCTV monitors or a DVR. It
provides a convenient way of supplying power to the SM1s, installer friendly termination of the cable runs and a standard
RCA or 3.5mm audio output connectors. The SMI17 easily connects to recording equipment such as DVRs, I/P cameras,
time-lapse VCRs and audio recorders. Note the audio output signal of the kit is “line level” (0dbm).
SM1 Microphone Placements
Locate the SM1 microphones as close as possible to the areas of interest in the spaces to be monitored. If large areas are
to be monitored, locate the SM1s in the middle of the rooms. Do not mount the microphone near air conditioning vents,
light fixtures or electrical equipment. The SM1 should be placed at least 5 feet away from the subject(s) to be monitored.
The SM1s are still useable in the range of 15-25 feet but is dependent on the level of background noise in the areas.
Experimentation in the environment will determine what distances work best.
Mounting
The SM1 can be surface or flush mounted on ceilings or walls. For flush mounting, cut a 2 ¼” by 2
¾
“ hole in the wall or
ceiling tile to allow room for the circuit board and mount the SM1 to the surface with screws. For surface mounting
applications, Purchase SM1-LEs. Or use single gang electrical boxes.
SMI16 location and power
The SMI16 interface box is designed to be located next to a DVR or I/P camera. The SMI16 requires a 120VAC power
source within 3 feet of its location. If this is not possible in your application, you can splice in up to 100 feet of 20 awg, 2
conductor cable to extend the distance between the AC power source and the SMI16.
Cable Runs
Run 16 each, 22 gauge, stranded, two conductor, shielded cables between the SMI16 interface and the SM1
microphones. Keep the cable run distances under 1,000 feet and away from AC power sources, light fixtures and
electrical equipment.
See Figure 1 for connection diagram.
Adjusting the SM1 Gain
Start with a midrange setting of the gain control on the SM1. Adjust the c or – for maximum clarity. If the sound at
the amplifier is distorted, rotate the control towards the – mark (counter- clockwise). If the volume at the amplifier is too
low, rotate the control towards the + mark (clockwise).
Setting the SM1 Jumpers
The SM1 microphone has jumper selectable treble boost and limiter circuits. The treble boost circuit when jumpered in,
emphasizes the high frequency sounds that the microphone picks up. This is useful for improving the sound quality on
slow speed tape recordings (VCR time-lapse recordings). The limiter circuit, when jumpered in, automatically reduces the
SM1’s output during loud sound intervals. This eliminates the need for the listener to reduce the volume control on the
amplifier when sounds get louder.
Note:
It is not recommended to use the SM1’s limiter circuit if you are using a tape recorder or other device that already
employs an AGC or limiter circuit. Most tape recorders have limiter circuits. The recommended jumper settings are as
follows:
Stand-alone Application
Tape Recorder Application
Limiter “IN”
“OUT”
Treble Boost
“OUT”
“IN”
Available from A1 Security Cameras