[20]
Turn the macro adjustment ring (15) counter
clockwise (left) as far as it will go and until you
feel no more restistance (Fig. 17).
Fig. 17
Carefully pull the grind size adjustment
including cone holder and cone burr
downwards out of the opening (Fig. 18).
Fig. 18
5.1.3. Cleaning
Clean the grinding chamber by pushing the bottle brush into the opening from above and moving it up and
down a few times. Clean the grind size adjustment including cone holder by removing any remaining coffee
grounds with the small brush.
Once in a while, also separate adjustment and coneholder and clean them independently from each other.
Ensure coneholder is perfectly snapped in when reassembling (watch the respective Video on our YouTube‐
channel “Replacing cone w/coneholder”).
5.1.4. Fitting the Grind Size Adjustment (14)
Position the grind size adjustment at the base of the opening. Ensure that the marker corresponds to the
marking at 8 o’ clock (Fig. 19).
Fig. 19