15
MAN20001512-01-03/22 (translation of the original operating instructions)
Operating Instructions
Key Adapter CKS2-K-BP/BR-CC-FLX
EN
9. Connection of a single CKS2 (separate operation)
If a single CKS2 is used, connect the device as shown in
. The monitoring output OD can be connected to a control
system.
WARNING
In the event of a fault, loss of the safety function due to incorrect connection.
Ì
To ensure safety, both safety outputs FO1A and FO1B must always be evaluated.
Important!
The example shows only an excerpt that is relevant for connection of the CKS2 system. The example
illustrated here does not show complete system planning. The user is responsible for safe integration
into the overall system. Detailed application examples can be found at www.euchner.com. Simply enter
the order number of your device in the search box. You will find all available connection examples for
the device in
Downloads
.
F-DI
6ES7148-4FC00-0AB0
Input Channel 0 und 4
1
24 V DC
2
In Ch.1
3
0 V DC
4
In Ch.2
5
n.c.
POWER SUPPLY
6ES7154-4AB10-0AB0
X03: 24 V IN
X04: 24 V OUT
1
1L+
-A1
2
1M
3
2L+
4
2M
1
1L+
2
1M
3
2L+
4
2M
5
FE
5
FE
Safety
Outputs
Readhead
Schlüssel/Key:
FO1B
4
0V
3
UB
1
FO1A
2
n.c.
5
-B1
EUC168921
1
2
-F1
24V DC
0 V
0 V
24V DC
Fig. 1:
Connection example for separate operation of a CKS2-K-BP-CC-FLX-… on a safe IP67 peripheral module