DANGER
Ì
If master keys or replacement keys are used, the operating organization must take suitable organi-
zational measures and use a corresponding risk assessment to prevent the system’s safety function
from being bypassed. For this purpose, observe the information in ISO/TS 19837.
WARNING
Danger to life due to improper installation or due to bypassing (tampering). Safety components fulfill
a personnel protection function.
Ì
Safety components must not be bypassed, turned away, removed or otherwise rendered ineffective.
On this topic pay attention in particular to the measures for reducing the possibility of bypassing
according to EN ISO 14119:2013, section 7.
Ì
The switching operation may be triggered only by keys specially designated for this purpose.
Ì
The key must be completely pulled out of the key adapter in order to switch the safety circuit off safely.
Ì
Mounting, electrical connection and setup only by authorized personnel possessing the following
knowledge:
-specialist knowledge in handling safety components
-knowledge about the applicable EMC regulations
-knowledge about the applicable regulations on operational safety and accident prevention.
Important!
Prior to use, read the operating instructions and the supplementary documents and keep them in a
safe place. Ensure the operating instructions are always available during mounting, setup and servicing.
For this reason you should archive a printed copy of the operating instructions. You can download the
operating instructions from www.euchner.com.