15
2097097-17-08/20 (Translation of the original operating instructions)
Operating instructions
Non-Contact Safety System CES-A-UBA-01/CES-A-UBA-01B
EN
10. System status table
Operating mode
Actuator/door position
Safety outputs A and B
PLC
LED indicator
Output
State
In-
put
Output
TST
OUT (status signal)
ERR
ST
ATE (gr
een)
OUT (yellow)
ERROR (r
ed)
Normal operation
closed
on
N
1
0
Normal operation, door closed
open
off
N
0
0
Normal operation, door open
State indication
X
off
X
0
0
3 x +
Self-test after operating voltage is applied
Fault display
X
off
N
0
1
Device-internal component failure or
excessively high external interference (EMC)
Function test
X
off
1
0
1
Function test active (TST input = 24 V)
Key to symbols
N
0 Volt or not connected
1
24 Volt
0
0 Volt
LED not illuminated
LED illuminated
3 x +
LED flashes three times and then illuminates continuously
X
Any state
Important!
If you do not find the displayed device status in the system status table, this indicates an internal device
fault. In this case, you should contact the manufacturer.