9
MAN20001437-01-10/21 (translation of the original operating instructions)
Operating Instructions
Transponder-Coded Safety Switch CTM-I2-BP/BR
EN
Using communication data on page 24
.
If no BR/IO-Link Gateway is connected, this output behaves like a monitoring output.
6.3.
Guard locking
Important!
Malfunctions due to incorrect use.
Ì
The actuator must not be under tensile stress during release.
The magnetically actuated guard locking operates in accordance with the open-circuit current principle. If the voltage is
interrupted at the solenoid, the guard locking is released and the guard can be opened directly.
The guard can be opened as long as no voltage is applied to the guard locking solenoid.
If a voltage is applied to the guard locking solenoid, the guard locking pin is held in the extended position and the guard is
locked.
6.3.1. Guard locking on version CTM-I2 and control via control input IMP
(guard locking actuated by power-ON and released by spring force)
Activating guard locking:
close guard, apply voltage to control input IMP.
Releasing guard locking:
interrupt voltage at control input IMP.
6.3.2. Guard locking on version CTM-I2 and control via IO-Link communication
Activating guard locking:
guard locking powered by the device’s operating voltage and controlled by bit
CL
(bit
CL
= 1).
Releasing guard locking:
guard locking released by spring force and deactivated by bit
CL
(bit
CL
= 0).