Manual EKS Electronic-Key Adapter USB
094485-04-11/13
Subject to technical modifications
Page 13/44
4.3 Connector assignment
4.3.1 USB interface socket
The socket on the Electronic-Key adapter is designed as USB type B.
4.3.2 Screw terminals of switching contacts LA1/LA2 and LB1/LB2 (only EKS FSA)
Information!
The coded plug for the connection of the switching contacts is included with the Electronic-Key adapter.
Coded plug 2 x 2-pole
with screw terminals
Cond. cross-section 0.14 … 1.5 mm²
Tightening torque 0.22 Nm
Channel
Pin
Function
LA
1
Normally open contact
channel LA
2
LB
1
Normally open contact
channel LB
2
4.4 DIP switch settings
Using the DIP switches S1 to S8, various parameters can be set.
Write protection can be enabled using DIP switch S1. In this way the writing of data to the read/write Electronic-
Key is prevented.
The settings are only applied when the power supply is switched on.
DIP switches, 8-pole:
1 2 3 4 5 6 7 8
ON
DIP
switch
Functions
Factory setting
S8
OFF = read/write Electronic-Key ON = read-only Electronic-Key*
OFF
S7
OFF
S6
OFF
S5
OFF
S4
OFF
S3
OFF
S2
OFF
S1
ON = write protection for read/write Electronic-Key
OFF
*
The read-only transponder type can also be read using the Electronic-Key adapter with USB interface. However, we do
not recommend using this transponder type in new installations. The read-only transponder cannot be used in
conjunction with the version EKS
FSA
.
Information!
It is
imperative
that all DIP switches without a function (S2 to S7) are set to
OFF
! In this way problems
with any functions added in the future will be avoided.
4.5 LED indicator
The Electronic-Key adapter operating states are indicated using a 2-color LED on the front.
The illumination of the LED in any color indicates the presence of the operating voltage.
Color
Operating state
Description
Green
Ready
Electronic-Key adapter supplied with power and ready.
Yellow
Electronic key active There is an Electronic-Key in the Electronic-Key adapter and it has been detected.