General data
Relay type
Electromechanical relay with positively driven contacts according to IEC/EN 61810-3
(EN 50205)
Nominal operating mode
100% duty cycle
Degree of protection
IP20
Minimum degree of protection of installation location
IP54
Mounting method
Rail mounting
Installation orientation
Vertical or horizontal
Mounting instructions
See derating curve
Housing version
PBT gray
Operating voltage indication
1 x LED green, yellow, red
State indication
5x LEDs, green
Air clearances and creepage distances between the circuits
According to
DIN EN 60947-1
Rated insulation voltage
320 V
Rated insulation voltage/insulation
See chapter “Insulation coordination”
Basic insulation 4 kV between all current paths and housing
Safe isolation, reinforced insulation 4 kV between input circuit and safety contact (13/14)
and safety contact (23/24)
Degree of contamination
2
Overvoltage category
II
Max. power dissipation at rated condition
6.45 W (US = 30 V, UL = 30 V, I² = 72 A²)
Note about power dissipation
See chapter “Calculating the power dissipation”
Dimensions
Housing
W x H x D
17.5 x 116.6 x 114.5 mm
Connection data
Spring terminals
Conductor cross-section, rigid
0.2 mm² … 1.5 mm²
Conductor cross-section, flexible
0.2 mm² … 1.5 mm²
Conductor cross-section, AWG/kcmil
24 … 16
Stripping length
8 mm
Ambient conditions
Ambient temperature (operation)
-25 °C … 60 °C (observe derating)
Ambient temperature (storage/transport)
-40 °C ... 85 °C
Max. perm. atmospheric humidity (operation)
75% (on average, 85% occasionally, no dew formation)
Max. perm. atmospheric humidity (storage/transport)
75% (on average, 85% occasionally, no dew formation)
Shock
15 g
Vibration (operation)
10 Hz …150 Hz, 2 g
Safety engineering data
Stop category according to IEC 60204
0
Safety engineering characteristics for IEC 61508 – high demand
Device type
Type A
HFT
1
SIL
3
PFH
D
1.00 x 10
-9
(4 A DC13; 5 A AC15; 8,760 operating cycles/year)
Demand rate
< 12 months
Proof-test interval
240 months
Mission time
240 months