Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
36
(Translation of the original operating instructions) 2500234-01-08/18
18. Technical data
NOTICE
If a data sheet is included with the product, the information on the data sheet applies.
Parameter
Value
Housing material
Fiber glass reinforced plastic
Die-cast zinc, nickel-plated,
Stainless steel,
Powder-coated sheet steel
Dimensions
See dimension drawing
Weight MGB2 (interlocking/locking module, without submodules)
1.0 kg
Weight handle module
1.1 kg
Weight escape release module
0.55 kg
Ambient temperature
-25 … +55 °C
Degree of protection
IP 65
1)
Safety class
III
Degree of contamination
3
Installation position
Any
Locking force F
zh
acc. to GS-ET-19
2000 N
Power supply
Via bus module MBM
Connection
M12, 5-pin (EUCHNER module plug connector MLI)
Current consumption, max.
2)
500 mA
Rated impulse withstand voltage U
imp
0.5 kV
Resilience to vibration and shock
Acc. to EN 60947-5-3
EMC protection requirements
Acc. to EN 61000-4
and DIN EN 61326-3-1
Risk times, max. (switch-off times)
3)
- Monitoring of the position of the guard
- Monitoring of guard locking
- Activation of guard locking
See information in the operating instructions for your bus module
Reliability values acc. to EN ISO 13849-1:2005
Category
4
Performance Level
PL e
MTTF
d
4)
820 years
DC
99%
Mission time
20 years
PFH
d
4)
- Monitoring of guard locking and the position of the guard
- Control of guard locking
- Monitoring of the position of the guard
- Evaluation of safety signals in submodules installed
2.62 x 10
-9
1) Only with correctly mounted connecting cables and submodules
2) Without submodules.
3) The risk time is the max. time between the change in the input status and the deletion of the corresponding bit in the bus protocol.