Operating Instructions Interlocking/Locking Modules
MGB2-I..-MLI-... / MGB2-L..-MLI-... (Modular)
6
(Translation of the original operating instructions) 2500234-01-08/18
Correct use includes observing the relevant requirements for installation and operation, particularly based on the following
standards:
Ì
EN ISO 13849-1, Safety of machinery – Safety-related parts of control systems – Part 1: General principles for design
Ì
EN ISO 14119, Safety of machinery – Interlocking devices associated with guards – Principles for design and selection
Ì
EN IEC 60204-1, Safety of machinery – Electrical equipment of machines – Part 1: General requirements.
Ì
EN IEC 62061, Safety of machinery – Functional safety of safety-related electrical, electronic and programmable elec-
tronic control systems.
The safety system MGB2-.-MLI... is only allowed to be combined with suitable MLI modules (see
Table 1: Combination options
for modules with MLI technology)
.
On the modification of system components, EUCHNER provides no warranty for function.
The customer is responsible for the safe overall function, especially for the safe integration into an overall system.
Important!
Ì
The user is responsible for the proper integration of the device into a safe overall system. For this
purpose, the overall system must be validated, e.g. in accordance with EN ISO 13849-2.
Ì
Correct use requires observing the permissible operating parameters (see chapter
18. Technical
data on page 36
).
Ì
If a data sheet is included with the product, the information on the data sheet applies.
Table 1: Combination options for modules with MLI technology
Bus module
Base units
Handle module
Submodules
Submodules
Submodules
MGB2-H-...
from V1.00.0
MSM-.-P-...
MSM-.-R-...
MSM-.-N-...
MSM-.-E-...
MSM-.-K-...
MBM-...-MLI
from V1.00.0
Interlocking/locking module
MGB2-I..-MLI/MGB2-L..-MLI
from V1.00.0
-
-
Extension module
MCM-...-MLI
-
-
Key to symbols
Combination possible
-
Combination not possible