Operating Instructions Safety Systems
MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C
26
(translation of the original operating instructions) 2123622-04-06/19
13.7.3. Additional button functions (only for configuration with expanded data structure)
Lamp control with MGB-PN in expanded mode
Lamp
Color
ON
OFF
Flashing
H90
White
Bit H90 = 1
Bit H90 = 0
-
H91
White
Door closed and
acknowledged
Door open
Door closed and not
acknowledged or escape
release operated
Blue
Door closed and locked via
bit from standard area and
acknowledged
All other states
-
Yellow
Door closed and locked
via bit from safe area and
acknowledged
All other states
-
Green
Door closed and locked
via bit from safe area and
from standard area and
acknowledged
All other states
-
H92
White
Bit H92 = 0
-
Blue
Bit H92 = 1
-
H94
Red
Bit H94=1 and emergency
stop not pressed and
acknowledged
Bit H94 = 0 and emergency
stop not pressed and
acknowledged
Emergency stop pressed
13.7.4. Data block for MGB locking module L2
MGB module
Slot
Required memory in data range of the control system (IO controller)
(refer to the data sheet of your device for the exact bit allocation)
Locking module
(configuration example)
-S7
See data sheet for slot as
-
signment
Input range
(1 byte)
Switch
ÜK
SK
-
-
-
Z
R
T
Bit
I0.7
I0.6
I0.5
I0.4
I0.3
I0.2
I0.1
I0.0
Output range
(1 byte)
Display
-
-
-
-
-
-
-
Guard
locking
solenoid
Bit
O0.7
O0.6
O0.5
O0.4
O0.3
O0.2
O0.1
O0.0
Bit allocation
Input range
Bit
Description
Output range
Bit
Description
I0.0
T (door position)
O0.0
S, guard locking solenoid – control voltage on
(function identical to bit
SO0.0
=> but control from PROFINET
area)
I0.1
R (bolt position)
O0.1
n.c.
I0.2
Z (guard locking)
O0.2
n.c.
I0.3
n.c.
O0.3
n.c.
I0.4
n.c.
O0.4
n.c.
I0.5
n.c.
O0.5
n.c.
I0.6
SK (T
AND
R)
O0.6
n.c.
I0.7
ÜK (T
AND
R
AND
Z)
O0.7
n.c.