27
2123622-04-06/19 (translation of the original operating instructions)
Operating Instructions Safety Systems
MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C
EN
13.8. Data blocks of individual functions at a glance
Function data blocks are required for all additional functions that are not included in the data blocks for MGB modules.
13.8.1. Data block for “standard” emergency stop function
Function
Slot
Required memory in data range of the control system (IO controller)
(refer to the data sheet of your device for the exact bit allocation)
Emergency stop
See data sheet for slot assign
-
ment
Input range
(1 byte)
Switch
-
-
-
-
-
-
-
S94
(aux-
iliary
contact)
Bit
I0.7
I0.6
I0.5
I0.4
I0.3
I0.2
I0.1
I0.0
Output range
(1 byte)
Display
-
-
-
-
-
-
-
H94
(LED)
Bit
O0.7
O0.6
O0.5
O0.4
O0.3
O0.2
O0.1
O0.0
Bit allocation
Input range
Bit
Description
Output range
Bit
Description
I0.0
Emergency stop auxiliary contact
O0.0
Emergency stop lighting.
For “standard” configuration:
control via this bit. 1 = ON, 0 = OFF
For “expanded” configuration:
controlled via the integrated lamp control system (in slot “ex-
panded PROFISafe 32 Bool IO”). See
functions (only for configuration with expanded data structure) on
I0.1
n.c.
O0.1
n.c.
I0.2
n.c.
O0.2
n.c.
I0.3
n.c.
O0.3
n.c.
I0.4
n.c.
O0.4
n.c.
I0.5
n.c.
O0.5
n.c.
I0.6
n.c.
O0.6
n.c.
I0.7
n.c.
O0.7
n.c.