Operating Instructions Safety Systems
MGB-L..B-PN.-… (PROFINET) and With Expanded Data Structure Type C
34
(translation of the original operating instructions) 2123622-04-06/19
Bit allocation for 1st byte
Input range
Bit
Description
Output range
Bit
Description
SI0.0
Emergency stop
SO0.0
Guard locking solenoid – control voltage on
(function identical to bit O0.0 in data block for MGB evaluation
module L0, L1 or L2 => but with safe control via PROFIsafe)
SI.01
Enabling switch
Enabling contacts closed (three-stage enabling switch in center
position), no evaluation of the edges
SO0.1
Emergency release
SI0.2
Door position (T)
SO0.2
n.c.
SI0.3
Bolt position (R)
SO0.3
n.c.
SI0.4
Guard locking (Z)
SO0.4
n.c.
SI0.5
Operating mode selector switch, 1st bit
SO0.5
Emergency stop control (ANH)
If this bit is set, the red lamp is switched on during emergency
stop. Attention: Internal light control is prioritized; see emergency
stop lamp.
SI0.6
Operating mode selector switch, 2nd bit
SO0.6
ENR
If this bit is set, this allows the emergency stop to be acknowl-
edged from the control panel. This is used in parallel with ac-
knowledgment button S91 in the MGB (OR); only the falling edge
is evaluated. This allows all emergency stops to be acknowl-
edged simultaneously from the panel.
SI0.7
Operating mode selector switch, 3rd bit
SO0.7
ETR
If this bit is set, this allows the SK and the ÜK to be acknowl-
edged from the control system. This is used in parallel with the
acknowledgment button in the MGB (OR); only the falling edge
is evaluated. This used for one-time acknowledgment from the
control system during system start-up.
Bit allocation for 2nd byte
Input range
Bit
Description
Output range
Bit
Description
SI1.0
SK (T
AND
R)
SO1.0
n.c.
SI1.1
ÜK (T
AND
R
AND
Z)
SO1.1
n.c.
SI1.2
n.c.
SO1.2
n.c.
SI1.3
n.c.
SO1.3
n.c.
SI1.4
n.c.
SO1.4
n.c.
SI1.5
n.c.
SO1.5
n.c.
SI1.6
n.c.
SO1.6
n.c.
SI1.7
Reserved for customer-specific function
SO1.7
n.c.