Operating Instructions Safety Systems
MGB-L0…-AR.-… and MGB-L0…-AP.-…
20
(translation of the original operating instructions) 112657-12-01/15
3 mm
9
10
11
OPEN
CLOSED
9
Remove cover and undo hexagon socket screw.
AT
Reposition the door handle by 90° in clockwise direction and fasten
it again.
AK
Tighten hexagon socket head screw to 3 Nm.
A
State after repositioning.
Figure 12: Changing actuating direction, steps
9
and
AK
Figure 13: Changing actuating direction, final state
10. Protection against environmental effects
Lasting and correct safety function requires that the system must be protected against foreign bodies such as swarf, sand,
blasting shot, etc., which can become lodged in the interlocking and handle modules. For this purpose a suitable installation
position should be selected.
Cover device during painting work!