9.2.2.12. SENSOR
Using the SENSOR function block the input status of a sensor (not a safety sensor) is checked. If the beam from the sensor
is obscured (output on the light barrier FALSE), the OUTPUT output is "0" (FALSE). Conversely, if this beam is not occupied
and the output on the sensor is "1" (TRUE), the OUTPUT output is "1" (TRUE).
Figure 105: Sensor
Parameter
Manual Reset: If selected, a reset can be requested each time the area protected by the sensor is occupied. Otherwise the
activation of the output will correspond directly to the input conditions.
There are two types of reset: "Manual" and "Monitored". On the selection of the manual reset, the system only checks the
signal transition from 0 to 1. With the monitored reset the double transition from 0 to 1 and then back to 0 is checked.
Important!
If manual reset is selected, the next input after the inputs used by the function block must be used.
Example: If Input1 is used for the function block, Input2 must be used for the reset input.
Manual
Monitored
Figure 106: Sensor manual/monitored reset