Output Test: Using this option you can select which test output signals are to be sent to the sensor. Short circuits between
the wires can be detected and rectified by means of this additional check. For this purpose it is necessary to configure the
test output signals (from the test output signals available).
StartUp Test: If selected, the test is undertaken on switching on the sensor. This test is undertaken by occupying and clearing
the area protected by the sensor to carry out one complete function test and to activate the OUTPUT output. This test is
only requested on starting the machine (on switching on the module).
Filter (ms): This parameter makes it possible to filter the signals that are received from the sensor. This filter can be set
to between 3 and 250 ms and removes any contact bounce. The time set for the filter affects the calculation of the total
response time of the module.
Enable Error Out: If selected, an error detected by the function block is displayed.
Item Description: Here you can enter a functional description for the component. This text is displayed in the upper part of
the symbol.