45
2121331-04-04/19 (Translation of the original operating instructions)
Operating Instructions
Modular Safety Control System MSC
EN
8.3.6. Module AC-FO2
MEANING
LED
RUN GREEN
IN F
AIL
RED
EXT F
AIL
RED
SEL
ORANGE
OSSD1/2
RED/GREEN
CLEAR1/2 YELLOW
ST
ATUS1/2 YELLOW
Switch on – initial CHECK
ON
ON
ON
ON
Red
ON
ON
Table 30:
Indication on star
ting
MEANING
LED
RUN GREEN
IN F
AIL
RED
EXT F
AIL
RED
SEL
ORANGE
OSSD1/2
RED/GREEN
CLEAR1/2 YELLOW
ST
ATUS1/2 YELLOW
NORMAL OPERA
TION
OFF
If the module is waiting for the first
message fr
om the base unit
FLASHING
If no INPUT or OUTPUT is r
equested
by the configuration
ON
If INPUT or OUTPUT is r
equested by
the configuration
OFF
Operation OK
OFF
Operation OK
Indicates the signal table
NODE_SEL0/1
RED
If output OFF
ON
W
aiting for RE
-
ST
ART
OUTPUT
state
GREEN
If output ON
Flashing
NO feedback loop
Table 31:
Dynamic indication
Figur
e 19:
AC-FO2
Summary of Contents for MSC