Accessible Toilet Alarm
N C 9 5 1 • D E S I G N & I N S T A L L A T I O N G U I D E
Approved Document No.: DNU0951001 Rev 3 • Page 1 of 8
R
ec
eption Are
as
A
cc
e ssible Toil
et
s
In
te
r view Roo
m
s
C
h
a n
g in g Roo
m
s
Single Zone Emergency Assistance Alarm
+
-
1
2
3
4
Indicators will operate:
Intermittently when help is on the way
R
RE
ES
SE
ETT
Indicators will operate:
Continuously when pull cord is activated
Intermittently when help is on the way
On
Calling
Call Accept
NC951
KIT CONTENTS
NC809DBBT
Accessible Toilet Reset Point c/w Sounder
Includes a ‘Reset’ button c/w braille text, red
reassurance LED and sounder.
NC807C
Ceiling Pull
Includes a red reassurance LED, red pull cord
and two triangular pull bangles.
NC949
Accessible WC
Sticker
NC943B
Single Zone Call Controller c/w Sounder
Includes a link selectable ‘Call Accept’/’Reset’
button, ‘Calling’ and power ‘On’ LEDs, 140mA PSU,
backup battery, volt-free relay output and sounder.
NC806CS
Overdoor Light c/w Sounder
Accessory Pack
Containing device
mounting screws
and shorting link.
Documentation
A Design & Installation
Guide (this document).
This equipment must be installed and maintained by a suitably skilled and technically
competent person.
This document provides a brief design and installation overview of the NC951 accessible
toilet alarm system, based on the recommendations of BS 8300 (the code of practice for the
design of buildings and their approaches to meet the needs of disabled people).