background image

10

Warning!

Following each battery exchange it is necessary to perform synchronization of the door 

handle set’s clock with the app’s clock, if synchronization is not performed the codes may 

not work correctly.

5. TECHNICAL SPECIFICATION

AC-01B9

AC-02B9

Power supply voltage

12V DC

Energy consumption - standby / operation

42 mA / 200 mA   

Capacity

no limit

Installation

Surface mounted

Housing material

Plastic

Bluetooth transmitter power output

4dB

Electromagnetic strike release time 

5-900 sek.   

Keypad 

Sensor

Proximity card reader frequency

13,56 MHz

Types of outputs

Output 1: relay N.C. & N.O. 1A/ 24VDC Max  

Output 2: N.O.  

(transistor) 50mA/12VDC Max 

Temperature operating range

-10ºC ~ +45ºC  

Protection coefficient

IP44

IP20

Dimensions (W x SZ x G) 

150 x 105 x 80 mm

115 x 75 x 22 mm

Net weight

215 g

115g

Summary of Contents for AC-01C9

Page 1: ...ACCESS CONTROL LOCKS Instruction manual AC 01C9 AC 02C9 ...

Page 2: ...4 2 INSTALLATION 4 3 MASTER SCHEMA 5 4 PROGRAMMING 6 4 1 ACCOUNT REGISTRATION IN TTLOCK MOBILE APP 6 4 2 LOGGING IN TO THE TTLOCK APP 7 4 3 ADDING DEVICE TO APP 7 4 4 OPERATING THE DEVICE 7 5 TECHNICAL SPECIFICATION 10 WARRANTY 11 ...

Page 3: ...g the content the user should contact the producer Unassisted assembling and start of the device can be done only with the use of proper tools However it is highly advised to set up a device by qualifed personnel The producer is not responsible for damages made during incorrect set up or mainte nance or in case of any unassisted repairs or modifcations ...

Page 4: ...with Mifare proximity reader Doorbell button Connection socket Tamper switch AC 01C9 Keypad with Mifare proximity reader Doorbell button AC 02C9 2 INSTALLATION outside rubber gasket inside rubber gasket Wall plugs raincover bracket keypad screw ...

Page 5: ...Doorbell 3 MASTER SCHEMA 12V DC electromagnetic strike exit button 12V GND NC COM NO SW IN OUT BELL BELL Schema of connecting the keypad with standard electromagnetic strike 12V GND NC COM NO SW IN OUT BELL BELL 12V DC electromagnetic strike exit button Schema of connecting the keypad with reverse electromagnetic strike ...

Page 6: ...the below instruction 4 1 ACCOUNT REGISTRATION IN TTLOCK MOBILE APP 4 1 1 in the upper right corner click Register 4 1 2 select registration mode by phone e mail 4 1 3 enter the phone number e mail address 4 1 4 set the password 4 1 5 select the verification code by clicking Get code 4 1 6 enter the code provided via text message e mail 4 1 7 provide answers to security questions in the case of th...

Page 7: ... add devices one by one and check if the device s keypad is illuminated 4 3 8 having selected the device the app will move automatically to the main menu of door handle set management 4 3 9 then select option Setting see item 4 4 8 and then Clock which opens the LOCK CLOCK page where the time shall be synchronized by clickingAdjust Clock 4 4 OPERATING THE DEVICE 4 4 1 The lock icon in the upper po...

Page 8: ...s possible to select the day of the week and hours for the code to work the code must be used at least once within 24 h since being established otherwise it loses expires 4 4 3 2 generate code by clicking Generate 4 4 3 3 click the icon of square with arrow in the upper right corner of the app 4 4 3 4 From the list select the code transmission method WeChat the code will be sent via WeChat app und...

Page 9: ...are card click the icon with three dots in the upper right corner select add IC Cards option enter the card name in the Name field select the access type permanent or timed in the case of a timed access being selected specify its period of validity click OK and wait for signal from the door handle set after the sound message place card near the 2 digit in the numerical keypad of the device All car...

Page 10: ...ption standby operation 42 mA 200 mA Capacity no limit Installation Surface mounted Housing material Plastic Bluetooth transmitter power output 4dB Electromagnetic strike release time 5 900 sek Keypad Sensor Proximity card reader frequency 13 56 MHz Types of outputs Output 1 relay N C N O 1A 24VDC Max Output 2 N O transistor 50mA 12VDC Max Temperature operating range 10ºC 45ºC Protection coefficie...

Page 11: ...ountries where Eura Tech has neither its own service network nor DOOR TO DOOR service the quality claims are dealt with by authorised distributors of the Eura products on the basis of the signed distribution agreements Within the framework of such agreements Eura Tech will ensure financing of the possible repairs and delivery of spare parts ...

Page 12: ... and modify the operating instructions without notification At the same time we would like to inform that the most up to date version of the manual can be found on the website www eura tech eu on the subpage of the given product The EU declaration of conformity of the given device is provided on the http www eura tech eu website 09 2019 Eura Tech Sp z o o hereby declares that the radio equipment t...