SD20-G Series
189
【
Note
】
For the drives with different encoder, the value of electronic gear ratio is
different, please pay attentions when using;
1
、
The value of incremental encoder is 10000; The value of rotation
transformer type encoder is 4096;
● Digital Output of E-cam
DO Name
FunOUT.14CAM_AREA
Function
DO
:
If it is ON
,
it means the position of E-cam axis is in the setting range
(1) User Parameter
1) Pulse Source Setting
Po374
Position Pulse Command Source Position
Setting Range
Setting Unit
Mfr’s Value
Effect
Four parameters
N/A
0001
Immediate effect
b
A
0
1
Low-speed pulse setting
B
0
1
High-speed counter setting
C
0
1
Internal position pulse setting
D
0
1
Electronic cam
Pulse is not from electronic cam.
Pulse is not from internal position.
Pulse is not from high-speed counter.
Pulse is not from low-speed pulse.
Pulse is from low-speed pulse.
Pulse is from high-speed counter.
Pulse is from internal position.
Pulse is from electronic cam.
2) Cam Control Setting
PL000
E-Cam Control Position
Setting Range
Setting Unit
Mfr’s Value
Effect
Four parameters
N/A
0000
Immediate effect
Summary of Contents for SD20-G Series
Page 35: ...SD20 G Series 35 M3 structure Fig 3 1 5 Servo drive structure 3...
Page 36: ...SD20 G Series 36 ML3 structure 118 5 5 7 5 93 297 8 223 118 93 0 5 12 5 7 5 4 M4...
Page 38: ...SD20 G Series 38 M4 structure Approx mass 10 365 kg Fig 3 1 7 Servo drive structure 5...
Page 39: ...SD20 G Series 39 M5 structure Approx msaa 11 1Kg Fig 3 1 8 Servo drive structure 6...
Page 40: ...SD20 G Series 40 M6 structure Approx mass 17 4Kg Fig 3 1 9 Servo drive structure 7...
Page 182: ...SD20 G Series 182 Fig 6 4 44SD20E Cam internal frameworkdiagram...