background image

PURIFICATION PROCESS 
AQUAGUARD

®

 ASTOR UV+UF

AQUAGUARD

®

 ASTOR UV+UF 

TECHNICAL SPECIFICATIONS*

UV disinfects the water by eliminating waterborne 
disease-causing bacteria, viruses and protozoa, 
thereby making it safe to drink.

i-Filter™

Multi-layered 
Polypropylene roving
wound cartridge 

Chemi-Block 
(with built-in 
Particle Trap 
Filter™)

Dust Free 
Bacteriostatic  
Activated Carbon 
Block 

Removes fine suspended particles such as dust, dirt, 
mud and sand from water. 

Reduces excess chlorine, bad odour, colour and 
organic impurities. It also removes very fine turbidity 
causing particles.

Ultra Filter

UF Hollow Fiber 

Capillary tube type membrane-based technology that 
imparts crystal clear clarity to drinking water in 
addition to making the water safe from bacteriological 
contamination. 

Germicidal UV Lamp

UV e-boiling

Copper has antimicrobial, antioxidant, and anti-inflammatory 
properties that help to support healthy metabolism. It also helps 
to provide the body with energy and is much needed for growth 
and development. The activated carbon removes organic 
components and polishes the water, giving it a sparkling look, 
making it pure and great to taste.

Bacteriostatic Taste 
Enhancer with Active 
Copper™ Technology

Active 
Copper™

1.

2.

3.

4.

5.

Aquaguard

®  

Astor UV+UF

Model

2

Dimension (W X D X H)  

320 mm X 278 mm X 476 mm

Net Weight

4.5 kg (Approx.)

3

Purification Technology

UV+UF

6.2 Litres (approx.)

4

Tank Capacity 

i-Filter™, Chemi-Block, UF Filter, UV e-boiling, 
Active Copper™

5

Standard Filtration 
Supplied   

1

1

Power Rating

20 Watts (Max.)

1

Input Iron (Max.)                           

0.3 mg/L

2

Total Dissolved Solids 
(TDS) (max.) 

Up to 200 mg/L

5

Input Water 
Temperature

10°C to 40°C

6

Input Chlorine Content 
(Max.)                           

0.2 mg/L

3

Input Water Turbidity 
(Max.)

5 NTU

4

Input Water Pressure 
Range**

0.3 to 2.0 kg/cm

2

1

UV Lamp

11 Watts

3

UV Lamp Life

8000 burning hours (as per manufacturer's spec.)

4

Operating Voltage Range

150VAC to 250 VAC, 50 Hz

5

Power Supply

Input 230VAC, 50Hz. Output: 12V.(ON Board AC -DC)

2

ELECTRICAL SPECIFICATIONS

RECOMMENDED INPUT WATER PARAMETERS

PRODUCT SPECIFICATION

*Technical Specifications are subject to change without prior notice.
Note: SMPS is designed to operate from 150VAC to 280VAC.
Note: The performance data presented in the table is applicable under standard laboratory conditions

#

Actual performance may vary depending on the input water quality, water pressure and condition of 
filters. Input water quality/pressure/TDS are important determinants of recovery rate and rejection.
**If the input water pressure is more than 2.0 kg/cm

2

, installation of a PRV (Pressure Reducing Valve) 

is mandatory. If the input water pressure is less than 0.3 kg/cm

2

, installation of a booster pump is 

recommended. 
These accessories are available at an extra cost.

Warranty void if not installed as per recommendations.

#

Standard Test Conditions: 

Feed Water Quality: TDS Max: 200 mg/L  
Pressure: 1 kg/cm

2

, Turbidity: 1 NTU (Max.), Temperature: 25°C, Chlorine: below 0.2 mg/L, 

Iron: below 0.3 mg/L, Life: 6000 liters

Power

Parameters

LED Indication UV+UF

Remarks

All LEDs

Red, Green, and Blue will glow one after other for 1 sec.

Blue LED will be Solid if Power is Available. 

Purification Process

Power

Service

Tank Full

Blue LED will be Solid

Red LED will be OFF

Green LED will Blink at 0.5 sec Rate for 30 secs

Blue LED will be Solid

Red LED will be OFF

Green LED will Blink at 0.5 sec Rate continuously

Blue LED Will be Solid

Red LED will be OFF

Green LED will be solid

Blue LED will be Solid

Red LED will be Solid 

Green LED will be OFF

Blue LED will be Solid

Red LED will Blink at 0.5 sec Rate

Green LED will be OFF

Blue LED will Blink at 0.25 sec Rate

Red LED will be OFF 

Green LED will be OFF

Tank filling mode

Storage (Tank Full)

UV Lamp Error 

SV Error

LPS

Power

Service

Tank Full

Power

Service

Tank Full

Power

Service

Tank Full

Power

Service

Tank Full

Power

Service

Tank Full

LED INDICATION CHART FOR
AQUAGUARD

®

 ASTOR UV+UF

HERE’S HOW YOUR AQUAGUARD

®

 

ASTOR RO WORKS 

PURIFICATION PROCESS IN YOUR 
AQUAGUARD

®

 ASTOR RO

AQUAGUARD

®

  ASTOR RO TECHNICAL

SPECIFICATIONS* 

Reduces TDS, hardness, pesticides and heavy metals like 
arsenic, lead and mercury. Eliminates microorganisms like 
bacteria, viruses, protozoa and cysts.

i-Filter™

Multi-layered 
Polypropylene roving
wound cartridge 

Chemi-Block 
(with built-in 
Particle Trap 
Filter™)

Dust Free 
Bacteriostatic  
Activated Carbon 
Block 

Removes fine suspended particles such as dust, dirt, 
mud and sand from water. 

Reduces excess chlorine, bad odour, colour and 
organic impurities. It also removes very fine turbidity 
causing particles.

Membrane 
Life Enhancer***

Special anti-scalant 
media

Prevents scaling of dissolved salts on the surface of 
the membrane, thereby enhancing the membrane life 
and performance.

Thin Film composite
(TFC) reverse 
osmosis membrane

Reverse
Osmosis 
Cartridge

Copper has antimicrobial, antioxidant, and anti-inflammatory 
properties that help to support healthy metabolism. It also 
helps to provide the body with energy and is much needed 
for growth and development. The activated carbon removes 
organic components and polishes the water, giving it a 
sparkling look, making it pure and great to taste.

Active 
Copper™

1.

2.

3.

4.

5.

Bacteriostatic Taste 
Enhancer with Active 
Copper™ Technology

Aquaguard

®

 Astor RO

Model

2

Dimension (W X D X H)  

320 mm X 278 mm X 476 mm

Net weight

6.2 kg (Approx.)

3

Purification Technology

RO

6.2 Litres (approx.)

4

Tank Capacity 

i-Filter™, Chemi Block, Reverse Osmosis Membrane, 
Active Copper™.

5

Standard Filtration 
supplied   

1

1

Power Rating

35 Watts (Max.)

1

Input Iron (Max.)                           0.3 mg/L

2

Total Dissolved Solids 
(TDS) (max.) 

Up to 2000 mg/L

5

Input Water 
Temperature

10°C to 40°C

6

Total Hardness

600 mg/L

7

Input Chlorine Content 
(Max.)                           

0.2 mg/L

3

Input Water Turbidity 
(Max.)

5 NTU

4

Input Water Pressure 
Range**

0.3 to 3 kg/cm

2

1

Operating Voltage Range

150VAC to 250 VAC

3

Power Supply

Input 230V AC, 50Hz./Output (internal AC/DC Adaptor) 
24V DC, 2.5 A

2

ELECTRICAL SPECIFICATIONS

RECOMMENDED INPUT WATER PARAMETERS

PRODUCT SPECIFICATION

++

HYBRID DIVERTER

VALVE

NOTE : THIS IS A SCHEMATIC ILLUSTRATION OF THE PRODUCT TO GIVE A VISUAL SCHEME OF WORKING OF UNITS. 

THIS IS NOT AN ACTUAL ENGINEERING DRAWING OF THE PRODUCT.

RAW WATER

INLET

 SV-24V

BOOSTER PUMP

LPS

DRAIN

FLOW 

 RESTRICTOR 

PURIFIED WATER

STORAGE TANK

FLOAT

DISC

MEMBRANE LIFE ENCHANCER

ACTIVE COPPER CARTRIDGE

 RO MEMBRANE

 I FILTER

CHEMI BLOCK

(WITH BUILT-IN PART

ICLE T

RAP F

ILT

ER)

( WATER FLOW DIAGRAM )

AQUAGUARD ASTOR  RO

*Technical Specifications are subject to change without prior notice.
Note: SMPS is designed to operate from 150VAC to 280VAC.
Note: The performance data presented in the table is applicable under standard laboratory conditions

#

Actual performance may vary depending on the input water quality, water pressure, turbidity and 
condition of filters. Input water quality/pressure/TDS are important determinants of recovery rate and 
rejection.
**If the input water pressure is more than 3.0 kg/cm

2

, installation of a PRV (Pressure Reducing Valve) 

is mandatory. If the input water pressure is less than 0.3 kg/cm

2

, installation of a booster pump is 

recommended.     
  If the input water TDS is more than 1000 ppm (mg/L) or input water hardness is more than 300 ppm 
(mg/L), use of a Membrane life enhancer is recommended. 
These accessories are available at an extra cost.

Warranty void if not installed as per recommendations.

#

Standard Test Conditions: 

Feed Water Quality: TDS Max: 1000 mg/L with NaCl 
Pressure: 1 kg/cm

2

, Turbidity: 1 NTU (Max.), Temperature: 25°C, Chlorine: below 0.2 mg/L, 

Iron: below 0.3 mg/L Life: 6000 liters, Pressure on membrane: 75 psi, Product recovery @ 25%

  ++

Membrane life enhancer is 
recommended to be installed 
if the TDS  is above 1000 ppm 
or hardness above 300 ppm

***Not a part of the product, Membrane life enhancer is recommended if the input water TDS is more than 1000 ppm 
(mg/L) or input water hardness is more than 300 ppm (mg/L). Available at extra cost

Reviews: