26
CHECKING OR REPLACING FUSES IN THE BATTERY CHARGER
To check or replace the fuses beneath the instrument panel proceed as follows:
Turn off the key and unplug the battery connector as specified in the previous paragraph;
Open the fuseholder cover (pos.1)
Replace the 15A fuse (pos.2) with a fuse of an equal amperage
CHECK THE SEAL ON THE COVER
The recovery tank cover seal ensures that a proper vacuum
is created inside the tank and this provides a better suction
performance on the squeegee.
It is very important to keep the seal intact in order for the
machine to work properly.
To clean and check the seal, proceed as follows:
Open the cover (see position 2);
Use a piece of cloth to wipe off the seal (see position 3)
and make sure it is not broken or damaged;
If the seal is damaged, remove it from the cover, mount
a new seal and make sure to fit the seam of the seal into
the rear position (see position 1);
Clean the area of the tank where the seal leans (see
position 4) when the cover is closed.
Summary of Contents for E51 BASE