27
RECHARGING BATTERIES
To charge the batteries follow the instructions below:
Bring the machine into a stop position in a flat surface area, turn it off and put on the brake (if
available);
Before charging the battery make sure to
scrupulously
follow
the
battery
charger
instruction manual provided with the machine;
Uncoil the cable from the cable reel located on board
the machine and connect the plug into a standard
electrical power socket.
The battery charger can run with a voltage range of
100-240 VAC.
WARNING:
WHEN
PLUGGING
THE
BATTERY
CHARGER
INTO
THE
ELECTRICAL SOCKET, THE MACHINE
FUNCTIONS
ARE
AUTOMATICALLY
DISABLED
There are 3 led lights located above the battery charger:
Position 2 “RED” light – position 3 “YELLOW” light – position 4 “GREEN" light
These lights indicate the charging status of the battery.
The GREEN light indicates that the charging cycle is completed and the plug can be disconnected from the electrical
socket and rolled back into the cable reel.
Once the battery is charged make sure to check the electrolyte level and if necessary fill it up only using distilled
water.
The battery must always be charged in ventilated areas.
The gas released during the charging process can cause explosions if it comes into contact with flames or sparks.
Battery acid should never come into contact with the eyes, skin or clothes, make sure to wear goggles, gloves and
appropriate clothing.
If it comes into contact with the eyes or skin, wash immediately with abundant water.
Do not place metal objects on the batteries.
Do not fill the batteries with sulphuric acid or other products.