background image

Installation Guide 

and Users Manual

Wall Mount Range Hood

AirPRO 238 Professional Series 

(PS29/PS31)

IMPORTANT:

Read and save these instructions.

NOTICE:

Installer:

 Leave this guide with the homeowner

Homeowner:

 Keep this guide for future reference

Summary of Contents for AirPRO 238 Professional Series

Page 1: ...nd Users Manual Wall Mount Range Hood AirPRO 238 Professional Series PS29 PS31 IMPORTANT Read and save these instructions NOTICE Installer Leave this guide with the homeowner Homeowner Keep this guide for future reference ...

Page 2: ......

Page 3: ...orities Before servicing or cleaning unit switch power OFF at service panel and lock service panel to pre vent power from being switched ON accidentally Clean grease laden surfaces frequently To reduce the risk of fire and to disperse air properly make sure to vent air outside DO NOT vent exhaust into spaces between walls crawl spaces ceiling attics or garages Ducted fans MUST always be vented to t...

Page 4: ...nge hood Clean ventilating fan frequently Always use appropriate cookware and utensils size Always use cookware appropriate for the size of the surface element To reduce the risk of injury to persons in the event of a stove top grease fire SMOTHER FLAMES with a close fitting lid cookie sheet or metal tray then turn OFF the burner BECAREFUL TO PREVENT BURNS NEVER PICK UPA FLAMING PAN you may be burne...

Page 5: ... Installation 10 11 Range hood operations 12 13 USE AND CARE Troubleshooting 14 Use and care information 15 Specifications 15 Measurements Diagrams 16 21 MAINTENANCE Cleaning 22 Replacing the filter light bulb 22 WARRANTY Coverage exceptions 23 Disclaimer Contact Us 24 Tools needed Page 3 Level Flat blade and Phillips screwdrivers Powered screwdriver or drill Measuring tape Utility knife Marker or p...

Page 6: ...4 PCS For sheet rock only Qty 2 PCS 30 in models Qty 3 PCS 36 in models Chimney mounting Bracket Qty 6 PCS Qty 4 PCS Qty 4 PCS plied Range Hood Lower Chimney Qty 2 PCS 30 in models Qty 3 PCS 36 in models Qty 4 PCS 30 in models Qty 6 PCS 36 in models Upper Chimney ...

Page 7: ...rtically through the roof through 6 15 3 cm or bigger round metal aluminum vent work The size of the vent should be uniform Use no more than three 90 elbows Make sure there is a minimum of 24 61 cm of straight vent between the elbows if more than one elbow is used DO NOT install two elbows together The length of vent system and number of elbows should be kept to a minimum to pro vide efficient perf...

Page 8: ...ld be no higher than 30 inch It is important to install the hood at the proper mounting height Hoods mounted too low could result in heat damage and fire hazard while hoods mounted too high will be hard to reach and will loose its performance and efficiency If available also refer to stove top manufacturer s height clearance requirements and recommended hood mounting height above range Due to differ...

Page 9: ...r terminate duct work into spaces between walls crawl spaces ceiling attics or garages All exhaust must be ducted to the outside Use metal aluminum duct work only Fasten all connections with sheet metal screws and tape all joints with certified Silver Tape or Duct Tape Use caulking to seal exterior wall or roof opening around the cap Vertical roof venting Roof cap Option 2 Side wall cap Horizontal ...

Page 10: ...lectrical inspector s use The range hood must be connected with copper wire plug only The range hood should be connected directly to the fused disconnect or circuit breaker box through flexible armored or non metallic sheathed copper cable A U L or C S A listed strain relief must be provided at each end of the power supply cable Wire sizes copper wire only and connections must conform with the rati...

Page 11: ...ions of the support mounting bracket holes vent cutout if used and power supply cable cutout on the ceiling Use drill and saber saw or keyhole saw to cut openings for power supply cable and vent see Venting requirements and Electrical requirements Pages 6 8 If venting to the outside install vent system see Venting Requirements Page 5 Use caulking to seal exterior wall or roof openings Disconnect m...

Page 12: ...3 3 Align hood mounting bracket to the screws on the wall and hook hood into place as shown in Figure 4 and 4 Figure 5 Tighten screws to secure hood to the wall CAUTION Make certain the range hood is secure before releasing For safety purpose pre drilled mounting holes are provided through the back of the hood For a more secure 5 installation use as many mounting holes as needed to secure from the...

Page 13: ...the lower chim 10 ney to the range hood as shown in Figure 8 To avoid scratching the chimney extend the upper chimney 11 slowly and carefully to the chimney mounting bracket and tigten screws as shown in Figure 9 To install baffle filters refer to Figure 10 for the following three 12 steps Angle baffle filter toward back of hood Slide the knob toward the metal filter handle and push up Release the knob...

Page 14: ...ton must be pressed before a Speed Control button can be activated NOTE The light setting will not be affected by the Power Control On Off button Press the Power Control On Off button once The four LED Speed Indicators above the Speed Control will flash if a Speed Control button is not pressed within 10 seconds power will be turn OFF automatically While the LED Speed Indicators are flashing press a ...

Page 15: ...the halogen lights are OFF press the Light Control button once to turn halogen lights ON at High intensity LED Light Indicator will light up Touch the Light Control button again will change the light intensity to Low Each touch of the Light Control button will cycle the light intensity through High Low and OFF Heating Lamp Control Heating lamps sold separately 120 Volt 250 Watt maximum Heating lam...

Page 16: ...r 6 hole and loosely secured Check if duct is clogged or if damper unit half cir cular flapper is not installed correctly or opening properly A tight mesh on a side wall cap unit might also cause restriction to the air flow The lights work but the blower is not spinning at all 4 is stuck or is rattling The blower might be jammed or scraping the bot tom due to shipping damage Please contact us im med...

Page 17: ...lters must be replaced immediately DO NOT operate blowers when filters are removed Never disassemble parts to clean without proper instruc tions Disassembly is recommended to be performed by qualified personnel only Read and understand all instructions and warnings in this manual before proceeding Page 15 Specifications3 Body Design Seamless Stainless Steel Satin Finish Glossy Piano Black Finish Powe...

Page 18: ... D P ation Overview C D Upper support frame Range hood Round duct exhaust Chimney mounting bracket A Air Movement Direction Upper chimney C D Hood mounting bracket B Qty 4 PCS For sheet rock only Qty 6 PCS Qty 4 PCS Qty 4 PCS C D B A Back of the range hood A ...

Page 19: ...Page 17 All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated P P P P 1 1 17 7 7 Overall ...

Page 20: ...Page 18 Overall without Chiminey All measurements in parenthesis are in millimeter All inch measurements are converted from millimeters thus inch measurements are estimated ...

Page 21: ...Page 19 Circuit Diagram Hood mounting Bracket ...

Page 22: ...e Handle 4 Chimney Mounting Bracket 16 Electrical Box Cover 5 Hood Mounting Bracket 17 Electrical Box Base 6 Power Cable 18 Halogen Light Transformer 7 Safety Screen 19 Electrical Panel 8 Locknut 20 Control Panel Assembly Panel 9 Squirrel Cage 21 Hood Casing 10 Air Chamber 22 Baffle Filter 30 in 2pcs 36 in 3pcs 11 Motor 23 Baffle Filter Handle Screw 12 Halogen Light 24 Baffle Filter Handle ...

Page 23: ...Air Chamber 5 Safety Screen 3 Squirrel Cage Electrical Assembly No Description No Description 1 Screws 3 16 x 3 8 6 Electrical Panel 2 Electrical Box Cover 7 Capacitor 3 Processor Board 8 Screws 3 16 x 3 8 4 Screws 3 16 x 3 8 9 Halogen Light Transformer 5 Electrical Box Base ...

Page 24: ... contact with stainless steel for extended periods Many of these compounds contain chemicals which may be harmful Rinse with water after ex posure and wipe dry with a clean cloth Cleaning Stainless Steel Baffle Filter IMPORTANT Drain oil from baffles spacers filters oil tunnels oil containers before oil and residue overflow Remove all baffles spacers filters grease tunnel and oil containers and discard ...

Page 25: ... or cracks due to abuse misuse freight damage or improper installation Damage of product caused by accident fire floods or act of God Euro Kitchen is not liable for and does not cover under warranty any loss of properties or any costs associated with removing servicing installing or determining the source of problems with Euro Kitchen products This warranty is valid in the United States and Canada I...

Page 26: ...arrier s agent and keep copy to support your claim Upon acceptance of items owner assumes responsibility for its safe arrival Report damages to the carrier and file a claim immediately Failure to do so may result in the denial of your claim The carrier will furnish you with necessary forms for filing a claim Damages caused during transit are not covered under our warranty Please contact us to file an...

Page 27: ...Your Notes Page 25 ...

Page 28: ...Euro Kitchen Inc 2341 Industrial Parkway West Hayward CA 94545 Ph 510 266 0099 Fax 510 266 6630 http www euro kitchen com ...

Reviews: