result in loss of adhesion. Allow the glue to harden for a minimum of six (6) hours before continuing with
electrical connection to minimize loss of adhesion.
!
b) Mounting at the screw holes:
!
!
Tools needed:
!
Screw driver
!
Drill with drill bit
!
4x M6 Screw Bolt
!
4x M6 Nut for Screw Bolt
!
4x M6 Washers
!
!
All ApolloFLEX panels have screw hole markings where holes may be drilled through the panel. ONLY drill
holes at these locations.
!
Due to different surfaces and roof types, there are many ways to mount using screws. The actual mounting
process will depend on the application.
!
The best method is to use a bolt and nut with plain washers, all made of stainless steel, on the top and bottom
of the solar panel. Hardware should be compatible with the solar panel and mounting surface to avoid galvanic
corrosion.
!
Pre-drill the holes according to the screw hole markings on the panel. Make sure not to use too much pressure
on the panel when drilling.
!
Make sure the screw hole is waterproof and insulated by inserting a sealant before the screw. Dekalin Dekasyl
MS-5 in recommended.
!
!
Mounting cable roof enclosure:
!
Tools needed:
!
Screw driver
!
Drill with drill bit
!
Putty knife
!
!
After choosing an optimal location, sketch around the enclosure with a pencil. In the middle drill a hole large
enough for the cable of the solar panel to fit through. Fit the cable through the roof enclosure and the hole.
Apply glue to the bottom of the enclosure and adhere it to the surface around the drill hole. Remove excess
glue with a putty knife. Allow the glue to adhere for a minimum of six (6) hours. Do not move or adjust
enclosure once glue has started to adhere.
!
!
6) Electrical Connection
!
To avoid short circuits and/or injury, cover the solar panel while making electrical connections.
!
!
All ApolloFLEX Mono solar panels must be used in conjunction with a solar charger controller. Failure to do so
may result in damaging the battery. Votronic charge controllers are recommended. ApolloFLEX solar panels
can also be connected to any other type of charge controller.
!
!
Important:
Make sure the charge controller you have chosen is compatible with the type of battery which you
are using.
!
!
Preparation:
!
Choose a mounting location for the solar charge controller. Follow the manufacturer’s instructions of how to
mount it. The recommended distance between solar charge controller and main battery is 1.5 meters. If you
are using the battery connection cable that comes with the ApolloFLEX Mono kit, a fuse is already integrated
into the cable. If not, attach a fuse to the positive (+) cable which is twice the amount of amps which are
produced by the panels.
!
Measure the length of cable needed to connect the ApolloFLEX Mono solar panel to the charge controller. If
the cable is too long, cut the cable to the appropriate length. Strip the wires and crimp an insulated ferrule
each to the end of the positive and negative wires. Using a ferrule allows for a more efficient electrical
connectivity than bare stranded wire.
!
!
When connecting to a 24V electrical system, you must connect two 12V panels in series. A 24V compatible
solar charge controller is also required.
!
!
Example of serial connection of solar panels see Picture 3
!
!
Example of parallel connection of solar panels see Picture 4
!
!
Connection:
!
a) Connect the solar charge controller to the main battery. Always observe correct polarity. Allow the controller
to initialize and recognize the battery.
!
b) Make sure the solar panel is covered.
!
c) Connect the solar panel to the solar charge controller. Always observe correct polarity.
!
!
Note: Euro-Line Solar GmbH takes no responsibility for damages on the module caused by wrong installation
and by not following this installation manual.
!
!
7) Technical Details
!
!
8) Maintenance and Care
!
ApolloFLEX Mono solar panels are designed for long product life and require no maintenance outside of
cleaning. If the angle of the installation of the solar panel is more than 5 degrees, normal rainfall should be
sufficient to keep the panel surface clean of dirt.
!
!
• Panels should be cleaned periodically to remove salt deposits, dirt, dust and bird droppings.
!
• Only water and mild nonabrasive cleaners should be used with a cloth.
!
• Do not use chemicals.
!
• Do not use sharp objects.
!
• Flat mounted panels may need to be cleaned more often.
!
• Biannual check of system wiring is recommended.
!
!
9) Customer Service
!
Should a technical problem arise, please contact the retailer from which you ordered the panel first. Most
problems can be solved easily with a telephone call.
!
• Always contact your retailer first before returning a module or charge controller.
!
Element
Description
Structural Plate
1 mm strong aerospace grade fiberglass
Junction box
IP65 junction box, salt-waterproof
Cable
Single cable, two core 1 mm
²
diameter, UV-Resistant, 5 meter length
Solar Cells
High-Efficient Monocrystalline solar cells
Front Sheet
ETFE fluorine polymer protective front sheet, high corrosion resistant, self-cleaning,
lightly structured