background image

17 

 

Always use the safety chain included. Drilling above your head is extremely dangerous and is not 

recommended. For the use of magnetic drilling machines on pipes, not-flat or non-magnetic 

materials, we refer to our catalogue or our website 

www.euroboor.com

 where several vacuum 

tightening systems, pipe clamping systems and Tube machines can be found.  

 

4.3 Switching motor on and off 

 

The motor unit can only be switched ON when the magnet is activated. To switch the motor ON, 

press the green button with marking “I”. To switch the motor OFF, press the red button with marking 

“O”. 

4.4 GYRO-TEC safety 

 

This Euroboor magnetic drilling machine is equipped with GYRO-TEC safety functionality. It features a 

gyroscopic sensor which detects acceleration and displacement in any direction. Whenever the 

machine recognizes a sudden or unwanted movement the motor will be shut down automatically by 

the machine’s electronics. This safety functionality offers protection to the user in various 

circumstances, such as: 

 

-

 

Sudden loss of magnetic force while in operation; 

-

 

Excessive vibration caused by incorrect drilling procedure, worn-out cutting tools, etc; 

-

 

Sudden displacement of the workpiece to which the magnetic drilling machine is attached. 

 

By the motor shutting down automatically, risk of damaging or hurting the machine, tools, workpiece 

and operator is reduced. 

 

Every time the motor is started, the machines electronics need a moment to run a systems check and 

initiate the safety system. The GYRO-TEC safety feature engages three seconds after the motor is 

started. 

 

It is very important to note that this functionality raises the safety level, but does not prevent the 

operator from using the machine incorrectly. The operator should always follow instructions 

described in this manual and take all necessary safety precautions.  

 

4.5 Power surge and fluctuation protection 

This machine is equipped with power surge and fluctuation protection, making the machine suitable 
for use in areas and workplaces where power supply is of less quality. 

The machine will shut down part of the electronics and the motor by itself when the machine cannot 
cope with insufficient or unreliable power supply. This prevents the control unit(s) in the machine 
from breaking by cause of power supply, and thus unexpected downtime and high repair cost. In 
such a situation the magnet will remain switched on. 

Power surge protection 

 

The machine is able to cope with voltage spikes up to 

4,000V (1-2

μs

)

.* 

 

Summary of Contents for ECO.40S+

Page 1: ...Don t forget to register your machine at www euroboor com register only when registered you benefit from extended warranty User manual V 1 0 EN Magnetic drilling machine with external motor cable and...

Page 2: ...demands from the market Our vision is focused on developing innovative portable tools that add value for our customers and facilitate them in their daily work We never lose sight of sustainability ti...

Page 3: ...1 Assembly 12 3 2 Prior to use 13 4 Using the machine 15 4 1 Control panel 15 4 2 Electromagnet 15 4 3 Switching motor on and off 17 4 4 GYRO TEC safety 17 4 5 Power surge and fluctuation protection 1...

Page 4: ...ds gases or dust A magnetic drilling machine may create sparks which could ignite the dust or fumes 3 Keep bystanders children and visitors away while operating a magnetic drilling machine Distraction...

Page 5: ...u MUST wear ear and eye protection Machine use and care 1 When using the machine on non horizontal surfaces you must use cutting paste Do not use oil because the oil can drip into the motor unit 2 Whi...

Page 6: ...shaped objects Always place the machine on a surface that is clear of shavings chips swarf and surface dirt Keep the magnet clean and free of debris and swarf Do not switch on the machine before check...

Page 7: ...ntation certain residual risks cannot be avoided These are Impairment of hearing Risk of personal injury from flying particles Risk of burns due to accessories becoming hot during operation Risk of pe...

Page 8: ...rs and twist drills and for countersinking in a weather protected environment using the application tools and accessories recommended by Euroboor The magnetic drilling machine can be used horizontally...

Page 9: ...1 x safety gloves 2 4 Serial number The serial number is mentioned on the machine three times engraved on the frame engraved on the magnet and on the serial no sticker on the motor housing Additional...

Page 10: ...240 V 50 60 Hz 2 6 Symbols Symbol Term meaning Explanation Read documentation Be absolutely sure to read the documentation in this user manual and specifically the General safety instructions and Spec...

Page 11: ...ns no No load speed Revolution speed at no load 2 7 Environmental Separate collection This product must not be disposed of with normal household waste Separate collection of used products and packagin...

Page 12: ...he magnet align the slots in the guard with the holes in the magnet 2 Fit the screws into the holes located in the side of the magnet WARNING Always use the safety guard Fitting the lubrication system...

Page 13: ...y are operating perfectly and as intended Check that moving parts are in perfect working order do not jam and check whether the parts are damaged All parts must be correctly installed and fulfill all...

Page 14: ...rilling machine Let the machine run in for a period of eight to ten hours before starting with big operations Do not load the machine too much during this run in period Never use the machine with seri...

Page 15: ...your magnetic drilling machine is designed for maximum ease of use and safety 1 Magnet switch 2 Motor switch 3 Magnet LED Indicator 4 2 Electromagnet Make sure the magnetic drilling machine is placed...

Page 16: ...ts up GREEN when generated magnetic force is sufficient 3 To deactivate the magnet press the same switch again WARNING Do not use this machine when LED indicator is RED Magnet may not generate suffici...

Page 17: ...ls etc Sudden displacement of the workpiece to which the magnetic drilling machine is attached By the motor shutting down automatically risk of damaging or hurting the machine tools workpiece and oper...

Page 18: ...g sure the issues with the power source is fixed o Connect the machine to a different and reliable power source Continue using the machine as described in this user manual 4 6 Carbon brushes This mach...

Page 19: ...more cutting lubricant when the shavings metal chips become blue Vertical and overhead applications Dip the cutter in cutting paste or apply an appropriate spray WARNING Do not use the lubrication sys...

Page 20: ...among material showing similar physical properties The drilling conditions are dependent on requirements for tool life and surface finish These conditions are further restricted by the rigidity of th...

Page 21: ...a regular pressure while drilling The drilling performance does not improve by putting more pressure on the machine Too much pressure will overload the motor and your annular cutter will be worn soone...

Page 22: ...e twist drill a Straight shank twist drills Use a Weldon drill chuck adapter such as Euroboor IBK 14 adapter 19 05 mm 3 4 Weldon external to 1 2 x 20 UNF to fit a drill chuck and straight shank twist...

Page 23: ...drill to position the machine in the correct position with the tip of the twist drill to meet the marked center of the hole Steps 3 12 see paragraph 5 1 Annular cutters Make sure the machine runs at m...

Page 24: ...h chemicals for cleaning the non metallic parts of the tool These chemicals may weaken the materials used in these parts Use a cloth dampened only with water and mild soap Never let any liquid get ins...

Page 25: ...nt Lubricating the feed travel The feed travel should be lubricated periodically with grease to ensure smooth operation Raise the motor unit to the highest position possible Lubricate the dove tail gu...

Page 26: ...e not mounted straight Dirt between spindle and triangular guide Motor starts running when magnet switch is turned on Damage or defective relay in control unit Motor making a rattling sound Gear ring...

Page 27: ...ng Wrong value fuse Defective magnet switch Defective control unit Defective magnet Fuse blows when motor is started Damaged or defective wiring Wrong value fuse Motor running roughly Defective armatu...

Page 28: ...28 8 Exploded views spare parts list 8 1 Exploded views...

Page 29: ...29...

Page 30: ...30...

Page 31: ...25 Pin 4 x 10 2 31 040S 0008 Gear box 1 32 030E 5033 Seal 2 33 030E 5034 Bearing nsk 6004 ddu 1 34 050 0106 Screw 4 8 x 45 4 35A 030E 5035 Spindle inc spring set 1 36 020 0136 Grub screw M8 x 8 2 No P...

Page 32: ...0 1008 Sensor 1 83 040S 1022 Magnet 220 Volt 1 040S 1022A Magnet 110 Volt No Part no Description Qty 200 040S 2010 Case ECO 40S with sticker 1 201 KSP Q2 Coolant tank Quick Connect 2015 1 202 KSP P Pi...

Page 33: ...33 8 3 Wiring diagram...

Page 34: ...his 12 month period can be extended to 24 months in total by registering the product on our website https euroboor com support register Service To maximize the lifetime of your Euroboor machine always...

Reviews: