Operating faults
When starting up
• The compressor does not work >
check that the wall socket is supplied with power by plugging in
another electrical appliance.
• The compressor never stops >
put your hand on the condenser (grill located on the back of the
appliance). If the condenser is cold, contact your retailer.
If the condenser is hot, set your cabinet (ST1) to the maximum temperature setting value. If the compressor
still does not stop, contact your retailer.
• The wine cabinet does not switch on >
contact your dealer.
ANY WORK CARRIED OUT BY TECHNICAL SERVICES NOT APPROVED BY ARTEVINO
SHALL RENDER THE WARRANTY NULL AND VOID.
THE USE OF A GLASS DOOR CAN AFFECT THE PERFORMANCE OF YOUR WINE CABINET
IN SOME EXTREME TEMPERATURE CONDITIONS.
Energy and technical features
Model
Temperature
Height
(mm)
Width
(mm)
Depth
(mm)
Weight
(Kg)
Accuracy
1 temperature models
OXYVD8WCOUS /
OXYVG8WCOUS
1
1825
680
690
86
+/- 3 °F
Electrical
power*
(Watts)
Consumption
(kWh/ 24hrs)*
Voltage**
(V)
Frequency**
(Hz)
Recommended T°
range
Min. T°
Max. T°
100
0.700
115
60
32°F
86°F
Annual energy
consumption AEc***
(Kwh/year)
Useful
volume
(litres)
Acoustic
emissions
(dB(A))
256
460
38
Model
Temperature
Height
(mm)
Width
(mm)
Depth
(mm)
Weight
(Kg)
Accuracy
2 temperatures
model
OXY2TVD6COUS
2
1825
680
690
92
+/- 3 °F
Electrical
power*
(Watts)
Consumption
(kWh/ 24hrs)*
Voltage**
(V)
Frequency**
(Hz)
Recommended T° range
Min. T°
Max. T°
110
0.900
115
60
54°F
86°F
Annual energy
consumption AEc***
(Kwh/year)
Useful
volume
(litres)
Acoustic
emissions
(dB(A))
329
445
38
* Measured with an external temperature of 77°F.
** Depending on the country, these values can vary; to find out the specific properties of your appliance, consult your appliance’s
product identification label.
*** Energy consumption calculated based on the result obtained over 24 hrs in standard test conditions. Actual energy consumption
depends on the appliance’s location and operating conditions.
This appliance is intended solely for storing wine.
Category of all models:2
Climate class: our appliances are designed to be used at an ambient temperature of 50°F - 90°F - Class SN – Nevertheless, refer to
the table of technical features above to find out the optimal performance for your product.
This model cannot be flush-fitted.