f) Connect range to gas supply at appliance pressure regulator using
adapters supplied with flexible connector. Rigid pipe may also be used.
See rating plate for type of gas range has been manufactured for.
g) Turn on main gas valve at meter, and relight pilots at other gas
appliances.
h) Apply a non-corrosive leak detection fluid to all joints and fittings in the gas
connection between the supply line shut-off valve and the range. Include
gas fittings and joints in the range if connections were disturbed during
installation. Check for leaks!. Bubbles appearing around fittings and
connections will indicate a leak. If a leak appears, turn off supply line gas
shut-off valve, tighten connections, turn on the supply line gas shut off
valve, and retest for leaks.
CAUTION: NEVER CHECK FOR LEAKS WITH A FLAME.
WHEN LEAK CHECK IS COMPLETE, WIPE OFF ALL RESIDUE.
i) Remove shipping polystyrene from ALL rangetop burners. This is to hold
the burners in place on the burner base for shipping purposes only.
CHECKING PRESSURE OF HOUSE PIPING SYSTEM
1) The appliance and its individual shutoff valve must be disconnected from
the gas supply piping system during any pressure testing of that system at
test pressure in excess of ½ lbs./sq. in. (3.5 kPa or 13.8 in. water column).
2) The appliance must be isolated from the gas supply piping system by
closing its individual manual shutoff valve during any pressure testing of
the gas supply piping system at test pressure equal to or less than ½
lbs./sq. in. (3.5 kPa or 13.8 in. water column).
GAS CONVERSION
All Ranges are equipped with both Natural Gas and LP Gas injectors as well
as a convertible appliance pressure regulator. The unit model number plate
states which gas it was adjusted for at the factory. To convert the unit to
either Natural gas or LP gas will require switching burner injectors, burner
adjustment for low flame and adjustment of the appliance pressure regulator
converter cap.
Inlet pressure to the appliance pressure regulator should be as follows for
both operation and checking of appliance pressure regulator setting:
Summary of Contents for verona pro VEFSGG30
Page 22: ...22 9880021100 CU 30P VERONA PRO 040413040413 Fig n 11 Fig n 12 ...
Page 23: ...23 9880021100 CU 30P VERONA PRO 040413040413 Fig n 13 Fig n 14 ...
Page 24: ...24 9880021100 CU 30P VERONA PRO 040413040413 Fig n 15 Fig n 16 ...
Page 25: ...25 9880021100 CU 30P VERONA PRO 040413040413 Fig n 17 Fig n 18 A Fig n 18 B Fig n 19 ...