4
Set points for the electronic board
The standard default values are shown for use by the service technician. Remember that, with the exception of the
preparation times for the portions,
the user is prohibited from changing the programming of the electronic
card, tampering with which could cause irreparable damage
.
The manufacturer declines all responsibility in the case of unauthorised intervention on the programming of the card
and any such programming will render null and void the guarantee.
Programme
Value checked
Value set number
01
immersion time button 1 left
40 seconds
02
immersion time button 2 left
90 seconds
03
immersion time button 3 left
150 seconds
04
immersion time button 4 left
600 seconds
05
immersion time button 1 right
60 seconds
06
immersion time button 2 right
120 seconds
07
immersion time button 3 right
180 seconds
08
immersion time button 4 right
600 seconds
09
water temperature
97°C*
10
hysteresis
00
11
left basket rising time
40 second tenths
12
draining time
30 second tenths
13
fan intervention temperature
40°C
14
left basket descending time
35 second tenths
15
low temperature time-out time
999 seconds
16
max.basket motion time
25 seconds
17
time for level alarm switch on
10 seconds
18
max time for refill
20 minutes
19
motion time to offload left basket
30 second tenths
20
right basket rising time
46 second tenths
21
right basket descending time
35 second tenths
22
motion time to off-load right basket
33 second tenths
23
interval motion baskets
20 seconds
24
part-load heating
01 minute
25
off
00
26
draining pause
0 off 1 on
To change the programming, except for the first 8 programmes, the programme switch on the electronic board must
be operated, or press keys 1 and 4 on the right at th
e same time, together with the “Time Set” key.
The method of programming is the same as illustrated in the previous paragraph for the portion preparation times.
N.B
:
If the machine is installed well above sea level, boiling temperature may be lower than the set-point
value. In this case the element is always connected because the set point is never reached. The machine
must therefore be calibrated approximately to a value of 2° C less than the boiling temperature.
WATER BOILING TEMPERATURES
Altitude above the sea-level
Temperature °C
200mt
99,3° C
400 mt
98,6° C
600 mt
97,9° C
800 mt
97,2° C
1000 mt
96,5° C
1200 mt
95,8° C
1400 mt
95,1° C
1600 mt
94,4° C
1800 mt
93,7° C
2000 mt
93,0° C
2200 mt
92,3° C
2400 mt
91,6° C
2600 mt
90,9° C
2800 mt
90,2° C
3000 mt
89,4° C