Set points for the electronic board 

The standard default values are shown for use by the service technician.  Remember that, with the exception of the 
preparation  times  for  the  portions, 

the  user  is  prohibited  from  changing  the  programming  of  the  electronic 

card, tampering with which could cause irreparable damage

The manufacturer declines all responsibility in the case of unauthorised intervention on the programming of the card 
and any such programming will render null and void the guarantee. 

 
Programme 

Value checked  

 

 

Value set number 

 

01 

 

immersion time button 1 left 

 

 

40 seconds 

02 

 

immersion time button 2 left 

 

 

90 seconds 

03 

 

immersion time button 3 left 

 

 

150 seconds 

04 

 

immersion time button 4 left 

 

 

600 seconds 

05 

 

immersion time button 1 right 

 

 

60 seconds 

06 

 

immersion time button 2 right 

 

 

120 seconds 

07 

 

immersion time button 3 right 

 

 

180 seconds 

08 

 

immersion time button 4 right 

 

 

600 seconds 

09 

 

water temperature 

 

 

 

97°C* 

10 

 

hysteresis 

 

 

 

 

00 

11 

 

left basket rising time 

 

 

 

40 second tenths 

12 

 

draining time 

 

 

 

 

30 second tenths 

13 

 

fan intervention temperature 

 

 

40°C 

14 

 

left basket descending time 

 

 

35 second tenths 

15 

 

low temperature time-out time 

 

 

999 seconds 

16 

 

max.basket motion time  

 

 

25 seconds 

17 

 

time for level alarm switch on 

 

 

10 seconds 

18 

 

max time for refill 

 

 

 

20 minutes 

19 

 

motion time to offload left basket 

 

30 second tenths 

20 

 

right basket rising time   

 

 

46 second tenths 

21 

 

right basket descending time 

 

 

35 second tenths 

22 

 

motion time to off-load right basket 

 

33 second tenths 

23 

 

interval motion baskets   

 

 

20 seconds 

24 

 

part-load heating 

 

 

 

01 minute 

25 

 

off 

 

 

 

 

 

00 

26 

 

draining pause   

 

 

 

0 off 1 on 

 
To change the programming, except for the first 8 programmes, the programme switch on the electronic board must 
be operated, or press keys 1 and 4 on the right at th

e same time, together with the “Time Set” key. 

The method of programming is the same as illustrated in the previous paragraph for the portion preparation times. 
 

N.B

If the machine is installed well above sea level, boiling temperature may be lower than the set-point 

value.  In  this  case  the  element  is  always  connected  because  the  set point is  never  reached.  The  machine 
must therefore be calibrated approximately to a value of 2° C less than the boiling temperature. 

 

 

WATER BOILING TEMPERATURES 

Altitude above the sea-level

 

 

Temperature °C 

200mt   

 

 

 

99,3° C 

400 mt   

 

 

 

98,6° C 

600 mt   

 

 

 

97,9° C 

800 mt   

 

 

 

97,2° C 

1000 mt 

 

 

 

96,5° C 

1200 mt 

 

 

 

95,8° C 

1400 mt 

 

 

 

95,1° C 

1600 mt 

 

 

 

94,4° C 

1800 mt 

 

 

 

93,7° C 

2000 mt 

 

 

 

93,0° C 

2200 mt 

 

 

 

92,3° C 

2400 mt 

 

 

 

91,6° C 

2600 mt 

 

 

 

90,9° C 

2800 mt 

 

 

 

90,2° C 

3000 mt 

 

 

 

89,4° C 

 

Summary of Contents for Pasta Chef PL6

Page 1: ...1 PL6 PL7 115 V SERVICE MANUAL Eurochef srl Viale delle Nazioni n 101 41122 Modena Italy Tel 39 059 315146 Fax 39 059 3160787 www eurochef it eurochef eurochef it ...

Page 2: ...s Eurochef declines all responsibility where improper use of the machine causes personal injury accidents or damages to property 2 SPECIFICATION AND TECHNICAL DATA Baskets working separately with different time scales Basket control with 4 pre set times for each basket PL6 with sauce heater PL7 without sauce heater Reprogramming times Keyboard operated Basin capacity 10 litres approx Water control...

Page 3: ...when the temperature of the water is higher than 90 C Electrical connection Ensure that the plant is well earthed according to IEC regulations and check that the current corresponds with that stated on the registration plate on the machine Finally check that the plant to which the machine is connected has the power shown on the registration plate There must be an automatic fused or thermally prote...

Page 4: ... 16 max basket motion time 25 seconds 17 time for level alarm switch on 10 seconds 18 max time for refill 20 minutes 19 motion time to offload left basket 30 second tenths 20 right basket rising time 46 second tenths 21 right basket descending time 35 second tenths 22 motion time to off load right basket 33 second tenths 23 interval motion baskets 20 seconds 24 part load heating 01 minute 25 off 0...

Page 5: ... the element becomes hot Pressing 2 the display shows U 2 which is the output of the air blower U 3 is the left hand motor when it lifts the basket and U 4 the same motor when it lowers the basket In order to test also the microswitch of the motor it is better to remove the baskets before making the test In this way the motor shaft can turn freely and the lever of the microswitch can enter and exi...

Page 6: ...malfunctioning of the probe A03 Non control of the left motor The signal indicates that the motor does not stop at the preset time which might be because 1 the cam on the motor itself has shifted or 2 the relevant microswitch is broken or 3 a total motion time of the basket was preset which is higher than the limit normally 25 seconds foreseen for programme 16 A04 Non control of the right motor As...

Page 7: ...7 PICTURE A MAIN SWITCH HEATING ELEMENT CONNECTOR KEYBOARD TEMPERATURE LEVEL WATER PROBE PROBE JUNCTION ...

Page 8: ...8 PICTURE B HEATING RELAY TRANSFORMER BLOWER ELECTRONIC BOARD SAUCES MICROSWITCH MOTOR OF THE THERMOSTAT LEFT BASKET ...

Page 9: ...9 PICTURE C SAUCE WARMER WATER TANK MICROSWITCH MOTOR OF THE RIGHT BASKET SOLENOID VALVE ...

Page 10: ...10 ...

Reviews: