Instruction Manual ZHK
V07-19.0
35/129
Figure 35:
Sealing agent (Sikaflex)
Figure 36:
Applying the sealing agent
Pulling together AHU sections
The AHU sections must be aligned precisely and the front sides shall be exactly parallel to the
other. If necessary, some minor corrections can be made by placing steel plates under the section.
The AHU sections can be pulled together with belts which attach on the base frame, as shown on
Figure 37:
Pulling AHU sections together
Figure 38:
Pulling AHU sections together (detail)
Remove external panels at butt joints
For aligning and connecting the delivery sections, the external panels shall be removed, unless
heat exchanger fittings or similar components prevent this.
Figure 39:
Removable external panels