Instruction Manual ZHK
86/129
V07-19.0
Connection scheme for electric heater according to EUROCLIMA:
Figure 184:
Connection scheme for electric heater
In case of dehumidification wheel downstream of electric heater, it is ensured that control rotates
the wheel while electric heater is on (additional enabling contact).
7.6.2
AHUs which are not equipped from EUROCLIMA with control
Supply of EUROCLIMA contains:
-
2 independent safety thermostats
-
assembly of the safety thermostats
The
safety related correct implementation of control
has to be carried out
on
site and is the full responsibility of the client to do so.
The minimum safety requirements described in
chapter 7.6.1
) have to be ensured and is the full responsibility of the customer to do so.
7.7
Differential pressure restriction for plate heat exchangers
7.7.1
General indications
Plate heat exchangers are only partly pressure resistant.
Through incorrect installation, commissioning or operation by the user of
the system, the pressure between supply and exhaust air in the plate heat
exchanger may rise inadmissibly and destroy it.
The damages are costly.
Enabling contact:
Fan is running