00053960.DOC, Version 1.0
13/16
INSTALLATION
Installing/Replacing the lamps
DANGER TO LIFE!
Only install the lamps with the device switched off!
Unplug from mains before!
The lamp has to be replaced when it is damaged
or deformed due to the heat!
CAUTION!
Before replacing the lamp, unplug mains lead and let the lamp cool down (approx. 5 minutes).
During the installation do not touch the glass-bulbs bare-handed! Please follow the lamp manufacturer's
notes!
Do not install lamps with a higher wattage! Lamps with a higher wattage generate temperatures the device
was not designed for. Damages caused by non-observance are not subject to warranty.
For the installation, you need three 230V/35W GU-10 lamps.
During the operation, the lamp reaches temperatures of up to 200° C.
Procedure:
Step 1: Remove the lamp protection grilles.
Step 2: If replacing the lamp, remove the old lamp from the lamp-socket.
Step 3: Insert the new 230V/35W GU-10 lamp into the lamp-socket.
Step 4: Replace the lamp protection grilles.
Attention: Never operate the device without the cloth cover. Danger of burns!
OPERATION
The device can be set up as desired or installed overhead. If the device is to be installed overhead the
following safety instructions are binding:
Overhead rigging
DANGER TO LIFE!
Please consider the valid standards and national regulation during the installation!
The installation must only be carried out by an authorized dealer!
The installation of the device has to be built and constructed in a way that it can hold 10 times the weight for
1 hour without any harming deformation.