00026882.DOC, Version 2.0
19/36
If the device will be directly connected with the local power supply network, a disconnection switch with a
minimum opening of 3 mm at every pole has to be included in the permanent electrical installation.
The device must only be connected with an electric installation carried out in compliance with the IEC-
standards. The electric installation must be equipped with a Residual Current Device (RCD) with a maximum
fault current of 30 mA.
OPERATION
After you connected the effect to the mains, the GF-10 starts running.
You can do without a controller as the GF-10 features a built-in microphone, which provides automatic sound
control.
On the rear panel of the GF-10, you can find two 3-step mode-selectors with the following functions:
Selector 1 (left) rotation
I Continuous beam-movement
0 Static light
II Sound-controlled beam-movement
Selector 2 (right) colour gobos
I Continuous beam-movement
0 Static light
II Sound-controlled beam-movement
CLEANING AND MAINTENANCE
The operator has to make sure that safety-relating and machine-technical installations are inspected by an
expert after every four years in the course of an acceptance test.
The operator has to make sure that safety-relating and machine-technical installations are inspected by a
skilled person once a year.
The following points have to be considered during the inspection:
1) All screws used for installing the devices or parts of the device have to be tighly connected and must not
be corroded.
2) There must not be any deformations on housings, fixations and installation spots (ceiling, suspension,
trussing).
3) The electric power supply cables must not show any damages, material fatigue (e.g. porous cables) or
sediments. Further instructions depending on the installation spot and usage have to be adhered by a
skilled installer and any safety problems have to be removed.
Disconnect from mains before starting maintenance operation!
DANGER TO LIFE!
We recommend a frequent cleaning of the device. Please use a moist, lint-free cloth. Never use alcohol or
solvents!
The lens has to be replaced when it is obviously damaged,
so that its function is impaired, e. g. due to cracks or deep scratches!
CAUTION!
The objective lens will require weekly cleaning as smoke-fluid tends to building up residues, reducing the
light-output very quickly. The venting slots should be cleaned monthly.