www.eurolite.de
28
DMX512 Operation
For operation with a controller with DMX512 protocol, the fog machine is equipped with 8 control channels.
To be able to operate the machine with a DMX controller, the DMX starting address must be set for the first
DMX channel. For this, press the button
MENU
so many times until “
Addr
“ is indicated in the display. Then
press
ENTER
to make your settings. Use the buttons ▲ and ▼ to set the address between
001
and
512
.
Once again, press
ENTER
to confirm your settings. You may now start operating the machine via your DMX
controller. The section below describes all functions of the 8 control channels.
Channel 1 – Fog output
DMX value
Function
000 – 009
off
010 – 255
on
Channel 2 – Brightness red LEDs
DMX value
Function
000 – 009
off
010 – 255
Dimming from 1 – 100%
Channel 3 – Brightness green LEDs
DMX value
Function
000 – 009
off
010 – 255
Dimming from 1 – 100%
Channel 4 – Brightness blue LEDs
DMX value
Function
000 – 009
off
010 – 255
Dimming from 1 – 100%
Channel 5 – Brightness red, green and blue LEDs (color mixing)
DMX-Wert
Funktion
000 – 009
off
010 – 255
Dimming from 1 – 100%
Channel 6 – Color change speed
DMX value
Function
000 – 009
off
010 – 255
slow
→
fast
Channel 7 – Strobe control
DMX value
Function
000 – 009
off
010 – 255
slow
→
fast
Channel 8 – Master dimmer
DMX value
Function
000 – 009
off
010 – 255
Dimming from 1 – 100%
Summary of Contents for NSF-350